HD6433044 Hitachi Semiconductor, HD6433044 Datasheet - Page 54

no-image

HD6433044

Manufacturer Part Number
HD6433044
Description
(HD64 Series) Hitachi Single-Chip Microcomputer
Manufacturer
Hitachi Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6433044A00FV
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6433044F16
Manufacturer:
HITACHI
Quantity:
5 530
Part Number:
HD6433044F16
Manufacturer:
IDT
Quantity:
3 198
Part Number:
HD6433044F16
Manufacturer:
HITACHI
Quantity:
648
Part Number:
HD6433044F16A00
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6433044F18
Manufacturer:
HITACHI
Quantity:
5 530
Part Number:
HD6433044F18
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6433044F18
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6433044F18M08
Manufacturer:
TI
Quantity:
403
Part Number:
HD6433044F18M08
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6433044F18M08
Manufacturer:
HITACHI/日立
Quantity:
20 000
2.6.5 Notes on Use of Bit Manipulation Instructions
The BSET, BCLR, BNOT, BST, and BIST instructions read a byte of data, modify a bit in the
byte, then write the byte back. Care is required when these instructions are used to access registers
with write-only bits, or to access ports.
The BCLR instruction can be used to clear flags in the on-chip registers. In an interrupt-handling
routine, for example, if it is known that the flag is set to 1, it is not necessary to read the flag ahead
of time.
2.7 Addressing Modes and Effective Address Calculation
2.7.1 Addressing Modes
The H8/300H CPU supports the eight addressing modes listed in table 2-11. Each instruction uses
a subset of these addressing modes. Arithmetic and logic instructions can use the register direct
and immediate modes. Data transfer instructions can use all addressing modes except program-
counter relative and memory indirect. Bit manipulation instructions use register direct, register
indirect, or absolute (@aa:8) addressing mode to specify an operand, and register direct (BSET,
BCLR, BNOT, and BTST instructions) or immediate (3-bit) addressing mode to specify a bit
number in the operand.
Table 2-11 Addressing Modes
No.
1
2
3
4
5
6
7
8
Addressing Mode
Register direct
Register indirect
Register indirect with displacement
Register indirect with post-increment
Register indirect with pre-decrement
Absolute address
Immediate
Program-counter relative
Memory indirect
39
Symbol
Rn
@ERn
@(d:16, ERn)/@(d:24, ERn)
@ERn+
@–ERn
@aa:8/@aa:16/@aa:24
#xx:8/#xx:16/#xx:32
@(d:8, PC)/@(d:16, PC)
@@aa:8