16 STATUS PORT
The Status port is used to indicate the state of the transmit and receive buffers in the MIDI Data port. The Status port
is read-only (Table 35). Status port Bit 6 is MIDI Transmit Busy, Bit 7 is MIDI Receive Buffer Empty. The remaining
bits in the Status port are RESERVED.
Bit 7 – MIDI Receive Buffer Empty
Bit 7 MIDI Receive Buffer Empty indicates the read state of the MIDI Data port (Table 36). If the MRBE bit is ‘0’, MIDI
Read/Command Acknowledge data is available to the host.
Acknowledge data is NOT available to the host.
The MPU-401 Interrupt output is active ‘1’ when the MIDI Receive Buffer Empty bit is ‘0’. The MPU-401 Interrupt
output is inactive ‘0’ when the MIDI Receive Buffer Empty bit is ‘1’. See Section “Interrupt” for more information.
Bit 6 – MIDI Transmit Busy
Bit 6 MIDI Transmit Busy indicates the send (write) state of the MIDI Data port and Command port (Table 37).
There are no interrupts associated with MIDI transmit (write) data.
SMSC DS – LPC47M112
TYPE
BIT
NAME
MPU-401 I/O BASE ADDRESS+1
MIDI RX
EMPTY
BUFFE
D7
R
R
0
1
0
1
STATUS PORT
STATUS PORT
MIDI TX
BUSY
D7
D6
D6
R
Table 36 - MIDI Receive Buffer Empty Status Bit
Table 37 - MIDI Transmit Busy Status Bit
D5
Table 35 - MPU-401 Status Port
R
0
MIDI Read/Command Acknowledge data is
available to the host.
MIDI Read/Command Acknowledge data is
NOT available to the host.
The MPU-401 interface is ready to accept a
data/command byte from the host.
The MPU-401 interface is NOT ready to
accept a data/command byte from the host.
DATASHEET
D4
R
0
Page 78
DESCRIPTION
DESCRIPTION
D3
R
0
If the MRBE bit is ‘1’, MIDI Read/Command
D2
R
0
D1
R
0
D0
R
0