Specifications of UPD70F3201YGC-YEU-A

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, PWM, WDT
Number Of I /o
68
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 2.7 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3201YGC-YEU-A
Manufacturer:
Renesas Electronics America
Quantity:
10 000
14.1.2 Switching modes between CSI1 and UART0
at the same time. Select CSI1 or UART0 in advance by using port mode control register 3 (PMC3) and port function
control register 3 (PFC3) (refer to 4.3.3 Port 3).
14.2 Configuration
read from the SIOn register.
334
CSI1 and UART0 of the V850ES/SA2 and V850ES/SA3 share pins, and therefore these interfaces cannot be used
Caution CSI1 or UART0 transmission/reception operations are not guaranteed if the mode is changed
Remarks 1. n = 0, 1
CSIn is controlled by the clocked serial interface mode register (CSIMn). Transmit/receive data can be written to or
(1) Clocked serial interface mode register n (CSIMn)
(2) Clocked serial interface clock selection register n (CSICn)
(3) Serial I/O shift register n (SIOn)
The CSIMn register is an 8-bit register for specifying the operation of CSIn.
The CSICn register is an 8-bit register for controlling the transmit operation of CSIn.
The SIOn register is an 8-bit register for converting between serial data and parallel data. SIOn is used for
both transmission and reception.
Data is shifted in (reception) or shifted out (transmission) beginning at either the MSB side or the LSB side.
Actual transmit/receive operations are controlled by reading or writing SIOn.
2. × = Don’t care
during transmission or reception. Be sure to disable the operation of the unit that is not used.
PMC3
After reset:
After reset:
PFC3
00H
00H
7
0
7
0
PMC3n
CHAPTER 14 CLOCKED SERIAL INTERFACE n (CSIn)
0
1
1
Figure 14-2. Selecting CSI1 or UART0 Mode
R/W
R/W
6
0
6
0
Address:
Address:
PFC3n
User’s Manual U15905EJ2V1UD
×
0
1
5
0
5
0
FFFFF446H
FFFFF466H
Port I/O mode
CSI1 mode
UART0 mode
4
0
4
0
Operation mode
3
0
3
0
PMC32
2
2
0
PMC31
PFC31
1
1
PMC30
PFC30
0
0