SAM3S4B Atmel Corporation, SAM3S4B Datasheet - Page 72

no-image

SAM3S4B

Manufacturer Part Number
SAM3S4B
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3S4B

Flash (kbytes)
256 Kbytes
Pin Count
64
Max. Operating Frequency
64 MHz
Cpu
Cortex-M3
# Of Touch Channels
23
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
10
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
48
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
10.7.3
10.7.4
72
SAM3S
Fault status registers and fault address registers
Lockup
Usually, the exception priority, together with the values of the exception mask registers, deter-
mines whether the processor enters the fault handler, and whether a fault handler can preempt
another fault handler. as described in
In some situations, a fault with configurable priority is treated as a hard fault. This is called prior-
ity escalation, and the fault is described as escalated to hard fault. Escalation to hard fault
occurs when:
If a bus fault occurs during a stack push when entering a bus fault handler, the bus fault does not
escalate to a hard fault. This means that if a corrupted stack causes a fault, the fault handler
executes even though the stack push for the handler failed. The fault handler operates but the
stack contents are corrupted.
Only Reset and NMI can preempt the fixed priority hard fault. A hard fault can preempt any
exception other than Reset, NMI, or another hard fault.
The fault status registers indicate the cause of a fault. For bus faults and memory management
faults, the fault address register indicates the address accessed by the operation that caused
the fault, as shown in
Table 10-12. Fault status and fault address registers
The processor enters a lockup state if a hard fault occurs when executing the hard fault han-
dlers. When the processor is in lockup state it does not execute any instructions. The processor
remains in lockup state until:
Handler
Hard fault
Memory
management fault
Bus fault
Usage fault
• A fault handler causes the same kind of fault as the one it is servicing. This escalation to hard
• A fault handler causes a fault with the same or lower priority as the fault it is servicing. This is
• An exception handler causes a fault for which the priority is the same as or lower than the
• A fault occurs and the handler for that fault is not enabled.
• it is reset
fault occurs because a fault handler cannot preempt itself because it must have the same
priority as the current priority level.
because the handler for the new fault cannot preempt the currently executing fault handler.
currently executing exception.
Status register
name
HFSR
MMFSR
BFSR
UFSR
Table
10-12.
“Exception model” on page
Address register
name
-
MMFAR
BFAR
-
Register description
“Hard Fault Status Register” on page
187
“Memory Management Fault Status
Register” on page 182
“Memory Management Fault Address
Register” on page 188
“Bus Fault Status Register” on page 183
“Bus Fault Address Register” on page
189
“Usage Fault Status Register” on page
185
63.
6500C–ATARM–8-Feb-11

Related parts for SAM3S4B