s3c2410a Samsung Semiconductor, Inc., s3c2410a Datasheet - Page 122

no-image

s3c2410a

Manufacturer Part Number
s3c2410a
Description
16/32-bit Risc Arm Microprocessor
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c2410a-20
Manufacturer:
SAMSUNG
Quantity:
15 995
Part Number:
s3c2410a-20
Quantity:
1 238
Part Number:
s3c2410a-20
Manufacturer:
SUNMNG
Quantity:
2 000
Company:
Part Number:
s3c2410a-20
Quantity:
130
Part Number:
s3c2410a-20-Y080
Manufacturer:
SAMSUNG
Quantity:
2 890
Part Number:
s3c2410a-20-Y0R0
Manufacturer:
SAMSUNG
Quantity:
523
Part Number:
s3c2410a20-Y080
Manufacturer:
SAMSUNG/三星
Quantity:
20 000
Company:
Part Number:
s3c2410a20-YO80
Quantity:
12 000
Company:
Part Number:
s3c2410a20-YO8N
Quantity:
1 619
ARM INSTRUCTION SET
BLOCK DATA TRANSFER (LDM, STM)
The instruction is only executed if the condition is true. The various conditions are defined in Table 3-2. The
instruction encoding is shown in Figure 3-18.
Block data transfer instructions are used to load (LDM) or store (STM) any subset of the currently visible registers.
They support all possible stacking modes, maintaining full or empty stacks which can grow up or down memory, and
are very efficient instructions for saving or restoring context, or for moving large blocks of data around main memory.
THE REGISTER LIST
The instruction can cause the transfer of any registers in the current bank (and non-user mode programs can also
transfer to and from the user bank, see below). The register list is a 16-bit field in the instruction, with each bit
corresponding to a register. A 1 in bit 0 of the register field will cause R0 to be transferred, a 0 will cause it not to be
transferred; similarly bit 1 controls the transfer of R1, and so on.
Any subset of the registers, or all the registers, may be specified. The only restriction is that the register list should
not be empty.
Whenever R15 is stored to memory the stored value is the address of the STM instruction plus 12.
3-40
31
Cond
28
27
100
25
24
24
P U
23
Figure 3-18. Block Data Transfer Instructions
22
S
21
W
[19:16] Base Register
[20] Load/Store Bit
0 = Store to memory
1 = Load from memory
[21] Write-back Bit
0 = No write-back
1 = Write address into base
[22] PSR & Force User Bit
0 = Do not load PSR or user mode
1 = Load PSR or force user mode
[23] Up/Down Bit
0 = Down: subtract offset from base
1 = Up: add offset to base
[24] Pre/Post Indexing Bit
0 = Post: add offset after transfer
1 = Pre: add offset bofore transfer
[31:28] Condition Field
20
L
19
Rn
16
15
Register list
0
S3C2410A