s3c2410a Samsung Semiconductor, Inc., s3c2410a Datasheet - Page 448

no-image

s3c2410a

Manufacturer Part Number
s3c2410a
Description
16/32-bit Risc Arm Microprocessor
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c2410a-20
Manufacturer:
SAMSUNG
Quantity:
15 995
Part Number:
s3c2410a-20
Quantity:
1 238
Part Number:
s3c2410a-20
Manufacturer:
SUNMNG
Quantity:
2 000
Company:
Part Number:
s3c2410a-20
Quantity:
130
Part Number:
s3c2410a-20-Y080
Manufacturer:
SAMSUNG
Quantity:
2 890
Part Number:
s3c2410a-20-Y0R0
Manufacturer:
SAMSUNG
Quantity:
523
Part Number:
s3c2410a20-Y080
Manufacturer:
SAMSUNG/三星
Quantity:
20 000
Company:
Part Number:
s3c2410a20-YO80
Quantity:
12 000
Company:
Part Number:
s3c2410a20-YO8N
Quantity:
1 619
MMC/SD/SDIO HOST CONTROLLER
SDI Data Status (SDIDSTA) Register
19-12
SDIDSTA
Read Wait
Request Occur
(RWaitReq)
SDIO Interrupt
Detect (IOIntDet)
FIFO Fail error
(FFfail)
CRC Status Fail
(CrcSta)
Data Receive CRC
Fail (DatCrc)
Data Time Out
(DatTout)
Data Transfer Finish
(DatFin)
Busy Finish
(BusyFin)
Reserved
Tx Data progress
On (TxDatOn)
Rx Data Progress
On (RxDatOn)
Register
SDIDSTA
0x5A000034
Address
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
[10]
Bit
[9]
[8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
R
R
Read wait request signal transmits to SD card. The request signal
is stopped and this flag is cleared by setting one to this bit.(for
SDIO)
0 = not occur,
SDIO interrupt detects. This flag is cleared by setting one to this
bit.(for SDIO)
0 = not detect,
FIFO fail error when FIFO occurs overrun / underrun / misaligned
data saving. This flag is cleared by setting one to this bit.
0 = not detect,
CRC Status error when data block sent (CRC check failed -
returned from card). This flag is cleared by setting one to this bit.
0 = not detect,
Data block received error (CRC check failed - calculated by host).
This flag is cleared by setting one to this bit.
0 = not detect,
Data / Busy receive timeout. This flag is cleared by setting one to
this bit.
0 = not detect,
Data transfer completes (data counter is zero). This flag is cleared
by setting one to this bit.
0 = not detect,
Only busy check finish. This flag is cleared by setting one to this
bit.
0 = not detect,
Data transmit in progress.
0 = not active,
Data receive in progress.
0 = not active,
R/(W)
R/W
SDI data status register
1 = data Tx in progress
1 = data Rx in progress
1 = receive crc fail
1 = Read wait request occur
1 = SDIO interrupt detect
1 = FIFO fail
1 = timeout
1 = data finish detect
1 = crc status fail
1 = busy finish detect
Description
Description
Reset Value
Initial Value
S3C2410A
0x0
0
0
0
0
0
0
0
0
0
0
0

Related parts for s3c2410a