CJ1W-NC234 Omron, CJ1W-NC234 Datasheet - Page 151

no-image

CJ1W-NC234

Manufacturer Part Number
CJ1W-NC234
Description
High Speed Pulse Train 2 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC234

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Present Position Preset
Timing Chart
The present position changes to the desired value which you set under [Direct Operation
Command Memory Area] the moment the present position preset signal in [Direct Operation
Command Memory Area] turns ON.
Thereafter, the operating condition changes to the origin confirmed status.
For the bit allocations, refer to "Direct Operation Command Memory Area" on page 5-64.
The following shows a timing chart.
When you change the present position to 0, it becomes the origin and thus the origin stop flag
turns ON.
Present position preset received
Positioning operation completed
Present position preset
Origin fix flag
ON
OFF
ON
OFF
ON
OFF
ON
OFF
4-4 Present Position Preset