CJ1W-NC234 Omron, CJ1W-NC234 Datasheet - Page 436

no-image

CJ1W-NC234

Manufacturer Part Number
CJ1W-NC234
Description
High Speed Pulse Train 2 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC234

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
9
9-2 Interrupt Feeding
9-11
Interrupt Feeding by Memory Operation
Positioning Control
Speed Control
Axis Parameter Settings
Memory Operation Data Settings
1. Selection of [Interrupt Signal Function Selection] under [IO Function Selection]
1. Setting of the sequence data [Command]
2. Execution of memory operation
1. Setting of the sequence data [Command]
2. Execution of memory operation
Use axis parameters and memory operation data to set interrupt feeding by memory operation.
For memory operation, refer to Chapter 7, Memory Operation.
For axis parameters other than those which this section explains, refer to "Axis Parameters"
on page 5-13.
Select an interrupt input as a trigger for interrupt feeding.
For details, refer to "I/O Function Selection" on page 5-19.
For memory operation data, refer to "Memory Operation Data" on page 5-83.
Just as the same as direct operation, the setting of memory operation data varies between
positioning control and speed control.
Set [Interrupt Feeding (Positioning Operation)] in the sequence data [Command].
For details on the setting method for sequence data, refer to "Interrupt Feeding (Positioning
Operation)" on page 7-25.
Execute memory operation.
For memory operation, refer to Chapter 7, Memory Operation.
Set [Interrupt Feeding (Speed Control)] in the sequence data [Command].
For details on the setting method for sequence data, refer to "Interrupt Feeding (Speed
Control)" on page 7-28.
Execute memory operation.
For memory operation, refer to Chapter 7, Memory Operation.
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)