5-3 Axis Parameters
5-17
Axis Type Setting
Virtual Axis
*1. For a 2-axis PCU, the default value is [2] for axis 3 and axis 4.
Set the axis type. When Virtual Axis or unused axis is selected, I/O wiring is not necessary.
Axis type becomes enabled at power supply ON, restart, or setup.
If you select [1: Virtual Axis] under axis type setting, you can use the axis as a Virtual Axis. A
Virtual Axis does not have any actual input/output and is used only for calculation purposes. In
a similar manner as a Physical Axis that actually outputs pulses, a Virtual Axis changes its
present position or status only on the PCU based on the command for each axis operation.
A Virtual Axis is different from a Physical Axis in the points below:
Synchronous Unit
operation function
setting
Axis Type
Parameter name
Select [Physical Axis] for axes that are actually wired to operate, and set [Unused Axis] for unused
All external inputs/outputs function as general-purpose inputs/outputs. However, only the interrupt
There is no servo unlock status. It is handled as servo lock status at all times.
The backlash compensation function is disabled, regardless of the settings.
axes.
The command present position is the only present position. The feedback present position value
is always the same as the command present position. An attempt to execute present position
preset to the feedback present position generates an error and fails.
input is an exception because you can use it as a latch input.
parameter is up to 500 kpps in the case of a Physical Axis. However, the upper limit becomes 4
Mpps for a Virtual Axis.
With the open collector output type, the setting range of the maximum speed for each axis
Reference
General name
Set the axis type.
0: Physical axis, 1: Virtual axis,
2: Unused axis
Synchronous Group Stop Selection
Synchronous Feeding Command Position Data
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Function
Parameter name
Setting range
0 to 2
Reference
5-49
page
Unit
At power supply
ON, restart or
Valid timing
Always
setup
Default
values
0
*1