CJ1W-NC434 Omron, CJ1W-NC434 Datasheet - Page 310

no-image

CJ1W-NC434

Manufacturer Part Number
CJ1W-NC434
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC434

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7
7-2 Memory Operation Data Settings
7-9
Edge Selection
Data 1 Area
Selection
Data 1 Word
Data 1 Bit
Data 2 Area
Selection
Data 2 Word
Data 2 Bit
Timer
Counter
Constant
Parameter
name
Select how to evaluate true/false of the conditional
expression.
0: Level assessment
1: Edge assessment
Specify the data 1 area for comparison.
0: Unit Control Memory Area (OUT/IN)
1: Manual Operation Command Memory area
2: Direct Operation Command Memory area
3: Memory Operation Command Memory area
4: Axis Status Memory area
5: Memory Operation Status Memory area
F: Constant (You can only set either data 1 or data
Specify the word position as the offset from the
beginning word, relative to the target area which
you specified by data 1 area selection.
Specify the bit position relative to the target word
which you specified by data 1 area selection and
data 1 word.
It is only enabled for the bit comparison.
Specify the data 2 area for comparison.
0: Unit Control Memory area (OUT/IN)
1: Manual Operation Command Memory area
2: Direct Operation Command Memory area
3: Memory Operation Command Memory area
4: Axis Status Memory area
5: Memory Operation Status Memory area
F: Constant (You can only set either data 1 or data
Specify the word position as the offset from the
beginning word, relative to the target area which
you specified by data 2 area selection.
Specify the bit position relative to the target word
which you specified by data 2 area selection and
data 2 word.
It is only enabled for the bit comparison.
Set the time to be applied when you specify a timer
for the conditional expression.
Specify the count to be applied when you specify a
counter for the conditional expression.
Set a constant when the condition is data
comparison and the data 1 or data 2 specifies a
constant.
2 in the data comparison)
2 in the data comparison)
Function
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Setting range
to 2147483647
−2147483648
0 to 10000
000F hex
000F hex
0 to 1000
0 to 255
0 to 255
0 to 15
0 to 15
0 to 5,
0 to 5,
0 to 1
10 ms
times
Unit
Default
values
0
0
0
0
0
0
0
0
0
0

Related parts for CJ1W-NC434