CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Error Messages
This section lists the error messages that can appear during operation and describes the
remedies for them.
An error was detected
during running.
Sequence No. xx
Error description: Memory
operation data error
An error was detected
during running.
Sequence No. xx
Error description: Memory
allocation failed.
Replaying speed can be
scaled by a value between
0.01 and 100.
(A value can be set to two
places of decimals.)
Effective sequence
numbers are 1 to 500.
Enter a value (The value
you entered has a format
error.)
Unspecified memory
operation command is
included.
Sequence No. xx
Simulation ends at the
above sequence No.
Message
7-10 Memory Operation Preview with CX-Programmer
There is a mistake in the
parameters set in the sequence
data.
There is not enough memory in
the computer you are using.
A number smaller than 0.01 or
larger than 100 was input in the
[Replay Speed] box.
A number smaller than 1 or larger
than 500 was input in the
[Sequence Start No.] box.
A character string or symbol was
input in the [Replay Speed] box or
[Sequence Start No.] box.
A command that is not supported
for the memory operation preview
is included in the memory
operation data.
Probable cause of error
Correct the parameter in sequence
number xx in the Memory Operation
Data List.
Increase the amount of available
memory on your computer.
Input a replay speed scale value
between 0.01 and 100.
Input a number between 1 and 500 in
the [Sequence Start No.] box.
Input a number between 0.01 and
100 in the [Replay Speed] box and a
number between 1 and 500 in the
[Sequence Start No.] box.
---
Remedy