8
8-4 Data Write with IOWR Instruction
8-31
IOWR Instruction Specification
C: Control Data
S: Rightmost Word Number of Transfer Source
This section explains the format of the IOWR instruction. For details, refer to "Instructions
Reference Manual (W474)" for the CS/CJ-series PLC.
Specify the parameter type of the data to be written
The amount of common, axis or memory operation parameters that are writable per instruction
corresponds to 1 Unit Address. You cannot write multiple parameters with 1 instruction.
The memory operation data and memory operation condition data that are writable per
instruction is within for 1 sequence or within the range of 1 condition. You cannot write the data
of multiple sequences or multiple conditions with 1 instruction.
Prepare the transfer data as follows in the word which you specified in S.
However, the transfer data for the feedback counter present value (parameter type: 1101 to
1104 hex) and external encoder axis count value (parameter type: 11F1 hex) are as follows:
Operand
Words
Words
IOWR
S+1
S+2
S+1
W
S
S
C
S
W
C
S
Unit address
Transfer data
Transfer data
Set the parameter type on the PCU in hexadecimal.
Specify the first word of the PLC where you set the data to be transferred.
W: PCU unit number of the transfer destination
W+1: Number of transfer words
Set data
Set data
@IOWR
Only one item per instruction in the case of parameters.
Data within 1 sequence in the case of memory operation data.
One condition in the case of memory operation condition data.
W
C
S
C: Control data
S: Beginning word number of transfer source
W: Transfer destination unit number and number of transfer words
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Set the Unit Address of the data to be transferred in hexadecimal.
Set the transfer data.
In the case of transferring data of 2 words, set the rightmost word
data in S+1 and the leftmost word data in S+2.
Set the transfer data (present value preset value).
Set the rightmost word data in S, and leftmost word data in S+1.
Explanation
in hexadecimal
Description
Description
.
Related parts for CJ1W-NC434
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
ANALOG IN, CJ1, 4CH, HIGH SPPE
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
High Speed Pulse Train 2 Axes
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
High Speed Pulse Train 2 Axes
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
High Speed Pulse Train 4 Axes
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CJ Profinet Master
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Ethernet I/P Module
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
HIGH SPEED COUNTER 500Khz 2 CH
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Isolated Universal Analog 4pt
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CJ1 CompoNet Master
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: