CJ1W-NC434 Omron, CJ1W-NC434 Datasheet - Page 463

no-image

CJ1W-NC434

Manufacturer Part Number
CJ1W-NC434
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC434

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Axis Parameter Settings
Synchronous
Group Stop
Selection
Parameter name
Synchronous Group Stop Selection
You can set 2 axis parameters in relation to the synchronous unit operation function:
[Synchronous Group Stop Selection] and [Synchronous Feeding Command Position Data].
Synchronous Data Refresh areas are allocated to the I/O areas 1,200 to 1,295 words in the
CPU.
You can set the CPU and PCUs, respectively, to exchange data between the CPU and the
allocated areas of each PCU.
Synchronous group stop selection supports bits 00 to 14 in the Synchronous Data Refresh
area 1,200 word. Select whether or not to stop axis movement when each bit turns ON.
Bit
00
01
02
03
04
05
06
Select the operation that takes place when bit 00
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 00.
1: Stop when bit 00 turns ON.
Select the operation that takes place when bit 01
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 01.
1: Stop when bit 01 turns ON.
Select the operation that takes place when bit 02
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 02.
1: Stop when bit 02 turns ON.
Select the operation that takes place when bit 03
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 03.
1: Stop when bit 03 turns ON.
Select the operation that takes place when bit 04
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 04.
1: Stop when bit 04 turns ON.
Select the operation that takes place when bit 05
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 05.
1: Stop when bit 05 turns ON.
Select the operation that takes place when bit 06
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 06.
1: Stop when bit 06 turns ON.
Function
10-2 Parameter Settings
Setting
range
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
Default
value
0
0
0
0
0
0
0
10-6
10