CJ1W-NC434 Omron, CJ1W-NC434 Datasheet - Page 552

no-image

CJ1W-NC434

Manufacturer Part Number
CJ1W-NC434
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC434

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
12
12-6 Error Code List
12-43
Category
Common Data Read
Data Write
Transfer Words
Count Invalid
Data Write CPU
Side Area Type
Invalid
Data Write CPU
Side Start Word
Invalid
Data Write NC
Unit Side Area
Type Invalid
Data Write NC
Unit Side Start
Word Invalid
Reflected Data
Transfer Error at
Data Write Setup
Data Write
Timeout
Transfer Words
Count Invalid
Data Read CPU
Side Area Type
Invalid
Data Read CPU
Side Start Word
Invalid
Data Read NC
Unit Side Area
Type Invalid
Data Read NC
Unit Side Start
Word Invalid
Data Read
Timeout
Item name
Error code
8211
8212
8213
8214
8215
8217
8221
8222
8223
8224
8225
8226
8227
The number of transfer
words for data read by a data
transfer bit is outside the
specified range.
The area type on the CPU
side is outside the specified
range for data read by a data
transfer bit.
The setting of the starting
word on the CPU side is
outside the specified range
for data read by a data
transfer bit.
The setting of the area type
on the PCU side is outside
the specified range for data
read by a data transfer bit.
The setting of the starting
word on the PCU side is
outside the specified range
for data read by a data
transfer bit.
Data read by a data transfer
bit was not successful.
The number of transfer
words for data write by a
data transfer bit is outside
the specified range.
The setting of the area type
on the CPU side is outside
the specified range for data
write by a data transfer bit.
The setting of the start word
on the CPU side is outside
the specified range for data
write by a data transfer bit.
The setting of the area type
on the PCU side is outside
the specified range for data
write by a data transfer bit.
The setting of the starting
word on the PCU side is
outside the specified range
for data write by a data
transfer bit.
Data write was executed by
a data transfer bit, in a
condition other than during
PCU setup, to a parameter
that becomes valid at power
supply ON, restart or setup.
Data write by a data transfer
bit was not successful.
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Cause
Check the number of data transfer
words.
Check the setting of the area type on the
CPU side.
Check the setting of the starting word on
the CPU side.
Check the setting of the area type on the
PCU side.
Check the setting of the starting word on
the PCU side.
Check the operating condition of the
CPU Unit, and then execute data read
again.
Check the number of data transfer
words.
Check the setting of the area type on the
CPU side.
Check the setting of the start word on the
CPU side.
Check the setting of the area type on the
PCU side.
Check the setting of the starting word on
the PCU side.
Any data write not during PCU setup
becomes invalid. Check the area type,
starting word and execution condition for
data write on the PCU.
Check the operating condition of the
CPU Unit, and then execute data write
again.
Release method