CJ1W-NC434 Omron, CJ1W-NC434 Datasheet - Page 190

no-image

CJ1W-NC434

Manufacturer Part Number
CJ1W-NC434
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC434

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
5
5-3 Axis Parameters
5-29
Command Position Unit Setting
*1. The default setting for an external encoder axis is [1].
*2. This setting range is based on the pulse unit.
Axis Feeding
Mode
Rotation Axis
Upper Limit
Display Unit
Command Pulse
Count Per Motor
Rotation
Work Travel
Distance Per
Motor Rotation
Unit Multiplier
Compensation
Ratio Numerator
Compensation
Ratio
Denominator
Starting Present
Position Clear
Enable
Parameter name
External
External
Select the coordinate system or unit system at the command position.
Command position unit setting becomes valid at power supply ON, restart, or setup.
External
Select the count mode of the command
position.
0: Linear axis (Finite length)
1: Rotation axis (Infinite length)
Set the rotation axis upper limit when you
set the AXIS FEEDING mode to rotation
axis.
Select the unit of command values.
0: pulse, 1: mm, 2: degree, 3: inch
Set the number of pulses per 1 motor
rotation.
Set the amount of the workpiece
movement per 1 motor rotation.
Set the magnification relative to the
amount of the workpiece movement per 1
motor rotation.
0: 1 time, 1: 10 times, 2: 100 times,
3: 1000 times, 4: 10000 times
Compensation ratio for position command
(numerator)
Compensation ratio for position command
(denominator)
Select whether to enable or disable the
preset function.
0: Disable, 1: Enable
Function
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Setting range
1073741823
1 to 1048576
1 to 1048576
4294967295
4294967295
0 to 1
1 to 3
0 to 4
0 to 1
1 to
1 to
1 to
*2
Command
Command
Pulse
Unit
unit
unit
1073741823
Default
values
10000
10000
0
0
0
1
1
0
*1