MC68376BAMFT20 Freescale Semiconductor, MC68376BAMFT20 Datasheet - Page 265

MC68376BAMFT20

Manufacturer Part Number
MC68376BAMFT20
Description
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68376BAMFT20

Cpu Family
68K/M683xx
Device Core
ColdFire
Device Core Size
32b
Frequency (max)
20MHz
Interface Type
QSPI/SCI
Program Memory Type
ROM
Program Memory Size
8KB
Total Internal Ram Size
7.5KB
# I/os (max)
18
Number Of Timers - General Purpose
2
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.25V
Operating Supply Voltage (min)
4.75V
On-chip Adc
16-chx10-bit
Instruction Set Architecture
RISC
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
160
Package Type
PQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68376BAMFT20
Manufacturer:
FREESCAL
Quantity:
245
13.4.3.1 Configuring the TouCAN Bit Timing
13.4.4 Error Counters
MC68336/376
USER’S MANUAL
The following considerations must be observed when programming bit timing func-
tions.
The TouCAN has two error counters, the transmit (TX) error counter and the receive
(RX) error counter. Refer to APPENDIX D REGISTER SUMMARY for more informa-
tion on error counters. The rules for increasing and decreasing these counters are de-
scribed in the CAN protocol, and are fully implemented in the TouCAN. Each counter
has the following features:
Table 13-8 Example System Clock, CAN Bit Rate and S-Clock Frequencies
System Clock
Frequency
• If the programmed PRESDIV value results in a single system clock per one time
• If the programmed PRESDIV value results in a single system clock per one time
• If the prescaler and bit timing control fields are programmed to values that result
• The TouCAN bit time must be programmed to be greater than or equal to nine
• 8-bit up/down counter
• Increment by 8 (RX error counter also increments by one)
• Decrement by one
• Avoid decrement when equal to zero
• RX error counter reset to a value between 119 and 127 inclusive, when the
• Following reset, both counters reset to zero
• Detect values for error passive, bus off and error active transitions
quantum, then the PSEG2 field in CANCTRL2 register should not be pro-
grammed to zero.
quantum, then the information processing time (IPT) equals three time quanta,
otherwise it equals two time quanta. If PSEG2 equals two, then the TouCAN
transmits one time quantum late relative to the scheduled sync segment.
in fewer than ten system clock periods per CAN bit time and the CAN bus loading
is 100%, anytime the rising edge of a start-of-frame (SOF) symbol transmitted by
another node occurs during the third bit of the intermission between messages,
the TouCAN may not be able to prepare a message buffer for transmission in time
to begin its own transmission and arbitrate against the message which transmit-
ted the early SOF.
system clocks, or correct operation is not guaranteed.
TouCAN transitions from error passive to error active
(MHz)
25
20
16
25
20
16
CAN Bit-Rate
(MHz)
0.125
0.125
0.125
1
1
1
CAN 2.0B CONTROLLER MODULE (TouCAN)
Possible S-Clock
Frequency (MHz)
1, 1.25, 2.5
1, 2, 2.5
10, 20
8, 16
1, 2
25
Possible Number of
Time Quanta/Bit
8, 16, 20
8,10, 20
10, 20
8, 16
8,16
25
PRESDIV Value + 1
25, 20,10
20, 10, 8
16, 8
2, 1
2, 1
1
MOTOROLA
13-9

Related parts for MC68376BAMFT20