MMC2107CFCPV33 Freescale Semiconductor, MMC2107CFCPV33 Datasheet - Page 469

no-image

MMC2107CFCPV33

Manufacturer Part Number
MMC2107CFCPV33
Description
IC MCU 33MHZ 128K FLASH 144-LQFP
Manufacturer
Freescale Semiconductor
Series
MCorer
Datasheet

Specifications of MMC2107CFCPV33

Core Processor
M210
Core Size
32-Bit
Speed
33MHz
Connectivity
EBI/EMI, SCI, SPI
Peripherals
POR, PWM, WDT
Number Of I /o
72
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LQFP
Data Bus Width
32 bit
Data Ram Size
8 KB
Interface Type
SCI, SPI
Maximum Clock Frequency
33 MHz
Number Of Programmable I/os
32
Number Of Timers
4 bit
Operating Supply Voltage
0 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No RoHS Version Available

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMC2107CFCPV33
Manufacturer:
AMD
Quantity:
1 001
Part Number:
MMC2107CFCPV33
Manufacturer:
MOTOLOLA
Quantity:
745
Part Number:
MMC2107CFCPV33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MMC2107CFCPV33
Manufacturer:
MOT
Quantity:
2
Part Number:
MMC2107CFCPV33
Manufacturer:
FREESCALE
Quantity:
20 000
18.10.6.2 External Trigger Single-Scan Mode
MMC2107 – Rev. 2.0
MOTOROLA
internally generate and act on a trigger event is very short, software can
momentarily read the status conditions, indicating that the queue is
paused. The trigger overrun flag is never set while in the
software-initiated single-scan mode.
The software-initiated single-scan mode is useful in these applications:
The external trigger single-scan mode is available on both queue 1 and
queue 2. The software programs the polarity of the external trigger edge
that is to be detected, either a rising or a falling edge. The software must
enable the scan to occur by setting the single-scan enable bit for the
queue.
The first external trigger edge causes the queue to be executed one
time. Each CCW is read and the indicated conversions are performed
until an end-of-queue condition is encountered. After the queue is
completed, the QADC clears the single-scan enable bit. Software may
set the single-scan enable bit again to allow another scan of the queue
to be initiated by the next external trigger edge.
The external trigger single-scan mode is useful when the input trigger
rate can exceed the queue execution rate. Analog samples can be taken
in sync with an external event, even though the software is not interested
in data taken from every edge. The software can start the external trigger
single-scan mode and get one set of data, and at a later time, start the
queue again for the next set of samples.
When a pause bit is encountered during external trigger single-scan
mode, another trigger event is required for queue execution to continue.
Software involvement is not needed to enable queue execution to
continue from the paused state.
Freescale Semiconductor, Inc.
For More Information On This Product,
Queued Analog-to-Digital Converter (QADC)
Allows software complete control of the queue execution
Allows the software to easily alternate between several queue
sequences
Go to: www.freescale.com
Queued Analog-to-Digital Converter (QADC)
Technical Data
Digital Control
469

Related parts for MMC2107CFCPV33