C8051F34A-GMR Silicon Labs, C8051F34A-GMR Datasheet - Page 206

no-image

C8051F34A-GMR

Manufacturer Part Number
C8051F34A-GMR
Description
8-bit Microcontrollers - MCU 48 MIPS 64KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F34A-GMR

Rohs
yes
Core
8051
Processor Series
C8051
Data Bus Width
8 bit
C8051F340/1/2/3/4/5/6/7/8/9/A/B/C/D
18.1. Enhanced Baud Rate Generation
The UART0 baud rate is generated by Timer 1 in 8-bit auto-reload mode. The TX clock is generated by
TL1; the RX clock is generated by a copy of TL1 (shown as RX Timer in Figure 18.2), which is not
user-accessible. Both TX and RX Timer overflows are divided by two to generate the TX and RX baud
rates. The RX Timer runs when Timer 1 is enabled, and uses the same reload value (TH1). However, an
RX Timer reload is forced when a START condition is detected on the RX pin. This allows a receive to
begin any time a START is detected, independent of the TX Timer state.
Timer 1 should be configured for Mode 2, 8-bit auto-reload (see
Timer with Auto-Reload” on page 237
occur at two times the desired UART baud rate frequency. Note that Timer 1 may be clocked by one of six
sources: SYSCLK, SYSCLK / 4, SYSCLK / 12, SYSCLK / 48, the external oscillator clock / 8, or an exter-
nal input T1. For any given Timer 1 clock source, the UART0 baud rate is determined by Equation 18.1.
Where T1
value). Timer 1 clock frequency is selected as described in
reference for typical baud rates using the internal oscillator is given in Table 18.1. Note that the internal
oscillator may still generate the system clock if an external oscillator is driving Timer 1.
18.2. Operational Modes
UART0 provides standard asynchronous, full duplex communication. The UART mode (8-bit or 9-bit) is
selected by the S0MODE bit (SCON0.7). Typical UART connection options are shown below.
206
CLK
is the frequency of the clock supplied to Timer 1, and T1H is the high byte of Timer 1 (reload
Detected
Start
Figure 18.2. UART0 Baud Rate Logic
RX Timer
Equation 18.1. UART0 Baud Rate
UartBaudRate
Timer 1
TH1
TL1
). The Timer 1 reload value should be set so that overflows will
Overflow
Overflow
Rev. 1.3
=
------------------------------ -
256 T1H
T1
Section “21. Timers” on page 235
CLK
Section “21.1.3. Mode 2: 8-bit Counter/
2
2
UART
1
-- -
2
RX Clock
TX Clock
. A quick