Specifications of R8A77850ANBGV

Core Processor
SH-4A
Core Size
32-Bit
Speed
600MHz
Connectivity
Audio Codec, MMC, Serial Sound, SCI, SIO, SPI, SSI
Peripherals
DMA, POR, WDT
Number Of I /o
108
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1 V ~ 1.2 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
436-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R8A77850ANBGV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
7. Memory Management Unit (MMU)
7.5.3
A TLB load instruction (LDTLB) is provided for recording UTLB entries. When an LDTLB
instruction is issued, this LSI copies the contents of PTEH and PTEL (also the contents of PTEA
in TLB extended mode) to the UTLB entry indicated by the URC bit in MMUCR. ITLB entries
are not updated by the LDTLB instruction, and therefore address translation information purged
from the UTLB entry may still remain in the ITLB entry. As the LDTLB instruction changes
address translation information, ensure that it is issued by a program in the P1 or P2 area.
After the LDTLB instruction has been executed, execute one of the following three methods
before an access (include an instruction fetch) the area where TLB is used to translate the address
is performed.
1. Execute a branch using the RTE instruction. In this case, the branch destination may be the
2. Execute the ICBI instruction for any address (including non-cacheable area).
3. If the LT bit in IRMCR is 0 (initial value) before executing the LDTLB instruction, the
Note that the method 3 may not be guaranteed in the future SuperH Series. Therefore, it is
recommended that the method 1 or 2 should be used for being compatible with the future SuperH
Series.
Rev.1.00 Jan. 10, 2008 Page 178 of 1658
REJ09B0261-0100
area where TLB is used to translate the address.
specific instruction does not need to be executed. However, note that the CPU processing
performance will be lowered because the instruction fetch is performed again for the next
instruction after MMUCR has been updated.
MMU Instruction (LDTLB)