R5F21236KFP#U0 Renesas Electronics America, R5F21236KFP#U0 Datasheet - Page 413

IC R8C/23 MCU FLASH 48LQFP

R5F21236KFP#U0

Manufacturer Part Number
R5F21236KFP#U0
Description
IC R8C/23 MCU FLASH 48LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/R8C/Tiny/23r
Datasheet

Specifications of R5F21236KFP#U0

Core Processor
R8C
Core Size
16-Bit
Speed
16MHz
Connectivity
CAN, I²C, LIN, SIO, SSU, UART/USART
Peripherals
POR, Voltage Detect, WDT
Number Of I /o
41
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
48-LQFP
For Use With
RCDK8C - KIT DEV EVAL FOR CAN R8C/23R0E521237CPE00 - EMULATOR COMPACT R8C/20/21/22/23
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
R5F21236KFP#U0R5F21236KFP#U1
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
R5F21236KFP#U0R5F21236KFP#V0
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
R5F21236KFP#U0R5F21236KFP#W4
Manufacturer:
Renesas Electronics America
Quantity:
10 000
R8C/22 Group, R8C/23 Group
Rev.2.00 Aug 20, 2008
REJ09B0251-0200
18.12 Reception and Transmission
Table 18.3
TrmReq
Configuration of CAN Reception and Transmission Mode
Table 18.3 shows Configuration of CAN Reception and Transmission Mode.
TrmReq, RecReq, Remote, RspLock, RemActive, RspLock: C0MCTLi register’s (i = 0 to 15) bit
When configuring a slot as a reception slot, note the following points.
When configuring a slot as a transmission slot, note the following points.
(1) Before configuring a slot as a reception slot, be sure to set the C0MCTLi registers (i = 0 to 15) to 00h.
(2) A received message is stored in a slot that matches the condition first according to the result of reception
(3) In normal CAN operation mode, when a CAN module transmits a message of which ID matches, the CAN
(1) Before configuring a slot as a transmission slot, be sure to set the C0MCTLi registers to 00h.
(2) Set the TrmReq bit to 0 (not transmission slot) before rewriting a transmission slot.
(3) A transmission slot should not be rewritten when the TrmActive bit is 1 (transmitting). If it is rewritten, an
0
0
1
1
0
mode configuration and acceptance filtering operation. Upon deciding in which slot to store, the smaller the
number of the slot is, the higher priority it has.
module never receives the transmitted data. In loop back mode, however, the CAN module receives back
the transmitted data. In this case, the module does not return an ACK.
indeterminate data will be transmitted.
RecReq
Configuration of CAN Reception and Transmission Mode
0
1
0
0
1
Page 391 of 501
Remote
-----
0
1
0
1
RspLock
1/0
-----
0
0
0
Communication environment configuration mode:
configure the communication mode of the slot.
Configured as a reception slot for a data frame.
Configured as a transmission slot for a remote frame. (At
this time the RemActive bit is 1.)
After completion of transmission, this functions as a
reception slot for a data frame. (At this time the RemActive
bit is 0.)
However, when an ID that matches on the CAN bus is
detected before remote frame transmission, this
immediately functions as a reception slot for a data frame.
Configured as a transmission slot for a data frame.
Configured as a reception slot for a remote frame. (At this
time the RemActive bit is 1.)
After completion of reception, this functions as a
transmission slot for a data frame. (At this time the
RemActive bit is 0.)
However, transmission does not start as long as RspLock
bit remains 1; thus no automatic remote frame response.
Response (transmission) starts when RspLock bit is set to
0.
Communication Mode of the Slot
18. CAN Module