HD64F2239TF20I Renesas Electronics America, HD64F2239TF20I Datasheet - Page 724

MCU 3V 384K I-TEMP 100-TQFP

HD64F2239TF20I

Manufacturer Part Number
HD64F2239TF20I
Description
MCU 3V 384K I-TEMP 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2200r
Datasheet

Specifications of HD64F2239TF20I

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2239TF20I
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 16 I
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10] Read the ICDR receive data.
[11] Clear the IRIC flag to 0. As in step [6], read the ICDR flag and clear the IRIC flag to 0
[12] The IRIC flag is set to 1 by the following two conditions.
Rev. 6.00 Mar. 18, 2010 Page 662 of 982
REJ09B0054-0600
(1) The flag is set at the falling edge of the 8th clock cycle of the receive clock for 1 frame.
(2) The flag is set at the rising edge of the 9th clock cycle of the receive clock for 1 frame.
Further data can be received by repeating steps [3] through [6].
Clear the TRS bit in ICCR to 0 to switch from transmit mode to receive mode. Clear the
ACKB bit in ICSR to 0 (acknowledge data setting). Clear the IRIC flag to 0, then set the
WAIT bit in ICMR to 1.
When ICDR is read (dummy data read), reception is started, and the receive clock is output,
and data received, in synchronization with the internal clock.
The IRIC flag is set to 1 by the following two conditions. At that point, an interrupt request
is issued to the CPU if the IEIC bit in ICCR is set to 1.
Read the IRTR flag in ICSR. If the IRTR flag value is 0, the wait state is cancelled by
clearing the IRIC flag as described in step [6] below. If the IRTR flag value is 1 and the next
receive data is the final receive data, perform the end processing described in step [7] below.
If the IRTR flag value is 1, read the ICDR receive data.
Clear the IRIC flag to 0. The reading of the ICDR flag described in step [5] and the clearing
of the IRIC flag to 0 should be performed consecutively, with no interrupt processing
occurring between them. During wait operation, clear the IRIC flag to 0 when the value of
counter BC2 to BC0 is 2 or greater. If the IRIC flag is cleared to 0 when the value of counter
BC2 to BC0 is 1 or 0, it will not be possible to determine when the transfer has completed. If
condition [3]-1 is true, the master device drives SDA to low level and returns an
acknowledge signal when the receive clock outputs the 9th clock cycle.
Set the ACKB bit in ICSR to 1 to set the acknowledge data for the final receive.
Wait for at least 1 clock cycle after the IRIC flag is set to 1 and then wait for the rising edge
of the 1st clock cycle of the next receive data.
Set the TSR bit in ICCR to 1 to switch from the receive mode to the transmit mode. The TSR
bit setting value at this point becomes valid when the rising edge of the next 9th clock cycle
is input.
consecutively, with no interrupt processing occurring between them. During wait operation,
clear the IRIC flag to 0 when the value of counter BC2 to BC0 is 2 or greater.
SCL is automatically held low, in synchronization with the internal clock, until the IRIC
flag is cleared.
The IRTR flag is set to 1, indicating that reception of 1 frame of data has ended. The
master device continues to output the receive clock for the receive data.
2
C Bus Interface (IIC) (Option)

Related parts for HD64F2239TF20I