AT91SAM7S256D-AU Atmel, AT91SAM7S256D-AU Datasheet - Page 337

no-image

AT91SAM7S256D-AU

Manufacturer Part Number
AT91SAM7S256D-AU
Description
ARM Microcontrollers - MCU 256K Flash SRAM 64K ARM based MCU
Manufacturer
Atmel
Series
SAM7S256r
Datasheet

Specifications of AT91SAM7S256D-AU

Rohs
yes
Core
ARM
Processor Series
AT91SAM
Data Bus Width
16 bit/32 bit
Maximum Clock Frequency
55 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT
Interface Type
2-Wire, I2S, SPI, USART
Length
7 mm

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S256D-AU
Manufacturer:
ATMEL
Quantity:
101
Part Number:
AT91SAM7S256D-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S256D-AU-999
Manufacturer:
Atmel
Quantity:
10 000
30.9
30.9.1
30.9.2
30.9.3
30.9.4
30.9.4.1
Slave Mode
The Slave Mode is defined as a mode where the device receives the clock and the address from another device
called the master.
In this mode, the device never initiates and never completes the transmission (START, REPEATED_START and
STOP conditions are always provided by the master).
Figure 30-23. Slave Mode Typical Application Block Diagram
The following fields must be programmed before entering Slave mode:
As the device receives the clock, values written in TWI_CWGR are not taken into account.
After a Start or Repeated Start condition is detected and if the address sent by the Master matches with the Slave
address programmed in the SADR (Slave ADdress) field, SVACC (Slave ACCess) flag is set and SVREAD (Slave
READ) indicates the direction of the transfer.
SVACC remains high until a STOP condition or a repeated START is detected. When such a condition is detected,
EOSACC (End Of Slave ACCess) flag is set.
In the case of a Read sequence (SVREAD is high), TWI transfers data written in the TWI_THR (TWI Transmit
Holding Register) until a STOP condition or a REPEATED_START + an address different from SADR is detected.
Note that at the end of the read sequence TXCOMP (Transmission Complete) flag is set and SVACC reset.
As soon as data is written in the TWI_THR, TXRDY (Transmit Holding Register Ready) flag is reset, and it is set
when the shift register is empty and the sent data acknowledged or not. If the data is not acknowledged, the NACK
flag is set.
Note that a STOP or a repeated START always follows a NACK.
1. SADR (TWI_SMR): The slave device address is used in order to be accessed by master devices in read
2. MSDIS (TWI_CR): Disable the master mode.
3. SVEN (TWI_CR): Enable the slave mode.
Definition
Application Block Diagram
Programming Slave Mode
Receiving Data
Read Sequence
or write mode.
Host with
Interface
Master
TWI
TWD
TWCK
Host with TWI
Interface
Slave 1
Host with TWI
Interface
Slave 2
LCD Controller
Slave 3
SAM7S Series [DATASHEET]
R
6175M–ATARM–26-Oct-12
R
VDD
337