AT91SAM7S256D-AU Atmel, AT91SAM7S256D-AU Datasheet - Page 420

no-image

AT91SAM7S256D-AU

Manufacturer Part Number
AT91SAM7S256D-AU
Description
ARM Microcontrollers - MCU 256K Flash SRAM 64K ARM based MCU
Manufacturer
Atmel
Series
SAM7S256r
Datasheet

Specifications of AT91SAM7S256D-AU

Rohs
yes
Core
ARM
Processor Series
AT91SAM
Data Bus Width
16 bit/32 bit
Maximum Clock Frequency
55 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT
Interface Type
2-Wire, I2S, SPI, USART
Length
7 mm

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S256D-AU
Manufacturer:
ATMEL
Quantity:
101
Part Number:
AT91SAM7S256D-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S256D-AU-999
Manufacturer:
Atmel
Quantity:
10 000
32.6.8
32.6.9
32.7
Figure 32-15. Receive Frame Format in Continuous Mode
Note:
The receiver can be programmed to receive transmissions from the transmitter. This is done by setting the Loop
Mode (LOOP) bit in SSC_RFMR. In this case, RD is connected to TD, RF is connected to TF and RK is connected
to TK.
Most bits in SSC_SR have a corresponding bit in interrupt management registers.
The SSC can be programmed to generate an interrupt when it detects an event. The interrupt is controlled by writ-
ing SSC_IER (Interrupt Enable Register) and SSC_IDR (Interrupt Disable Register) These registers enable and
disable, respectively, the corresponding interrupt by setting and clearing the corresponding bit in SSC_IMR (Inter-
rupt Mask Register), which controls the generation of interrupts by asserting the SSC interrupt line connected to
the AIC.
Figure 32-16. Interrupt Block Diagram
SSC Application Examples
The SSC can support several serial communication modes used in audio or high speed serial links. Some standard
applications are shown in the following figures. All serial link applications supported by the SSC are not listed here.
Loop Mode
Interrupt
1. STTDLY is set to 0.
TXBUFE
ENDTX
RXBUFF
ENDRX
PDC
RD
Transmitter
Receiver
Start = Enable Receiver
TXEMPTY
RXSYNC
TXSYNC
OVRUN
To SSC_RHR
TXRDY
RXRDY
DATLEN
Data
SSC_IER
To SSC_RHR
Set
DATLEN
SSC_IMR
Data
Interrupt
Control
SSC_IDR
Clear
SAM7S Series [DATASHEET]
SSC Interrupt
6175M–ATARM–26-Oct-12
420

Related parts for AT91SAM7S256D-AU