Specifications of AT91SAM7S256D-AU

Rohs
yes
Core
ARM
Processor Series
AT91SAM
Data Bus Width
16 bit/32 bit
Maximum Clock Frequency
55 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT
Interface Type
2-Wire, I2S, SPI, USART
Length
7 mm

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S256D-AU
Manufacturer:
ATMEL
Quantity:
101
Part Number:
AT91SAM7S256D-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S256D-AU-999
Manufacturer:
Atmel
Quantity:
10 000
Refer to chapters 8.4.5 and 9.4.5 of the Universal Serial Bus Specification, Rev. 2.0 for more information on the STALL
handshake.
ISOERROR: A CRC error has been detected in an isochronous transfer.
Read:
0 = No error in the previous isochronous transfer.
1 = CRC error has been detected, data available in the FIFO are corrupted.
Write:
0 = Resets the ISOERROR flag, clears the interrupt.
1 = No effect.
• TXPKTRDY: Transmit Packet Ready
This flag is cleared by the USB device.
This flag is set by the USB device firmware.
Read:
0 = Can be set to one to send the FIFO data.
1 = The data is waiting to be sent upon reception of token IN.
Write:
0 = Can be written if old value is zero.
1 = A new data payload is has been written in the FIFO by the firmware and is ready to be sent.
This flag is used to generate a Data IN transaction (device to host). Device firmware checks that it can write a data payload
in the FIFO, checking that TXPKTRDY is cleared. Transfer to the FIFO is done by writing in the UDP_ FDRx register. Once
the data payload has been transferred to the FIFO, the firmware notifies the USB device setting TXPKTRDY to one. USB
bus transactions can start. TXCOMP is set once the data payload has been received by the host.
After setting or clearing this bit, a wait time of 3 UDPCK clock cycles and 3 peripheral clock cycles is required before
accessing DPR.
• FORCESTALL: Force Stall (used by Control, Bulk and Isochronous Endpoints)
Read:
0 = Normal state.
1 = Stall state.
Write:
0 = Return to normal state.
1 = Send STALL to the host.
Refer to chapters 8.4.5 and 9.4.5 of the Universal Serial Bus Specification, Rev. 2.0 for more information on the STALL
handshake.
Control endpoints: During the data stage and status stage, this bit indicates that the microcontroller cannot complete the
request.
Bulk and interrupt endpoints: This bit notifies the host that the endpoint is halted.
The host acknowledges the STALL, device firmware is notified by the STALLSENT flag.
SAM7S Series [DATASHEET]