LPC47M182 SMSC Corporation, LPC47M182 Datasheet - Page 174

no-image

LPC47M182

Manufacturer Part Number
LPC47M182
Description
ADVANCED I/O CONTROLLER WITH MOTHERBOARD GLUE LOGIC
Manufacturer
SMSC Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC47M182-NR
Manufacturer:
SMSC
Quantity:
1
Part Number:
LPC47M182-NR
Manufacturer:
SMSC
Quantity:
6 382
Part Number:
LPC47M182-NR
Manufacturer:
SMSC
Quantity:
20 000
Part Number:
LPC47M182-NW
Manufacturer:
LINEAR
Quantity:
1 630
Part Number:
LPC47M182-NW
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
LPC47M182-NW
Manufacturer:
SMSC-Pbf
Quantity:
6
Part Number:
LPC47M182-NW
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
LPC47M182-NW
Quantity:
500
Part Number:
LPC47M182E-NW
Manufacturer:
Microchip Technology
Quantity:
10 000
11.2
Revision 1.8 SMSC/Non-SMSC Register Sets (02-24-05)
Chip Level (Global) Control/Configuration Registers[0x00-0x2F]
The chip-level (global) registers lie in the address range [0x00-0x2F]. The design MUST use all 8 bits of
the ADDRESS Port for register selection. All unimplemented registers and bits ignore writes and return
zero when read.
The INDEX PORT is used to select a configuration register in the chip. The DATA PORT is then used to
access the selected register. These registers are accessible only in the Configuration Mode.
Config Control
Default = 0x00
on VCC POR,
VTR POR and
HARD RESET
Logical Device #
Default = 0x00
on VCC POR,
VTR POR,
SOFT RESET and
HARD RESET
Card Level
Reserved
Device ID
Hard wired = 0x74
Device Rev
Hard wired
= Current Revision
REGISTER
0x03 - 0x06 Reserved - Writes are ignored, reads return 0 .
0x08 - 0x1F Reserved - Writes are ignored, reads return 0 .
ADDRESS
CHIP (GLOBAL) CONTROL REGISTERS
0x07 R/W
0x02 W
0x20 R
0x21 R
0x00 -
0x01
Table 11.3 – Chip Level Registers
CHIP LEVEL, SMSC DEFINED
DATASHEET
Reserved - Writes are ignored, reads return 0.
The hardware automatically clears this bit after the
write, there is no need for software to clear the bit.
Bit 0 = 1: Soft Reset.
Bits 7:1 Reserved
Refer to the “Configuration Registers” table for the
soft reset value for each register.
A write to this register selects the current logical
device. This allows access to the control and
configuration registers for each logical device.
Note: The Activate command operates only on the
selected logical device.
A read only register which provides device
identification. Bits[7:0] = 0x74 when read.
A read only register which provides device revision
information. Bits[7:0] = current revision when read.
174
DESCRIPTION
Advanced I/O Controller with Motherboard GLUE Logic
SMSC LPC47M182
Datasheet

Related parts for LPC47M182