UPD70F3738GF-GAS-AX Renesas Electronics America, UPD70F3738GF-GAS-AX Datasheet - Page 508

no-image

UPD70F3738GF-GAS-AX

Manufacturer Part Number
UPD70F3738GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3738GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3738GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
506
Cautions 1. A write operation to bit 0 is ignored.
2. Changing the ADA0M1.ADA0FR2 to ADA0M1.ADA0FR0 bits is prohibited while A/D
3. In the following modes, write data to the ADA0M0, ADA0M2, ADA0S, ADA0PFM, or
4. To select the external trigger mode/timer trigger mode (ADA0TMD bit = 1), set the high-
5. When not using the A/D converter, stop A/D conversion by setting the ADA0CE bit to 0
ADA0ETS1
ADA0TMD
conversion is enabled (ADA0CE bit = 1).
ADA0PFT registers while A/D conversion is stopped (ADA0CE bit = 0), and then enable
A/D conversion (ADA0CE bit = 1).
If the ADA0M0, ADA0M2, ADA0S, ADA0PFM, and ADA0PFT registers are written in other
modes during A/D conversion (ADA0EF bit = 1), the following will be performed,
according to the mode.
speed conversion mode (ADA0M1.ADA0HS1 bit = 1). Do not input a trigger during the
stabilization time that is inserted once after A/D conversion is enabled (ADA0CE bit =
1).
to reduce power consumption.
ADA0EF
Normal conversion mode
One-shot select mode/one-shot scan mode in high-speed conversion mode
In software trigger mode
A/D conversion is stopped and started again from the beginning.
In hardware trigger mode
A/D conversion is stopped, and the trigger standby status is set.
0
0
1
1
0
1
0
1
ADA0ETS0
Software trigger mode
External trigger mode/timer trigger mode
A/D conversion stopped
A/D conversion in progress
0
1
0
1
Specification of external trigger (ADTRG pin) input valid edge
No edge detection
Falling edge detection
Rising edge detection
Detection of both rising and falling edges
CHAPTER 14 A/D CONVERTER
User’s Manual U18953EJ5V0UD
A/D converter status display
Trigger mode selection
(2/2)

Related parts for UPD70F3738GF-GAS-AX