UPD70F3738GF-GAS-AX Renesas Electronics America, UPD70F3738GF-GAS-AX Datasheet - Page 823

no-image

UPD70F3738GF-GAS-AX

Manufacturer Part Number
UPD70F3738GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3738GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3738GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
21.9 Periods in Which Interrupts Are Not Acknowledged by CPU
acknowledged between an interrupt request non-sample instruction and the next instruction (the interrupt is held
pending).
21.10 Cautions
21.10.1 Restored PC
starts.
instructions, the execution of that instruction stops and resumes following completion of interrupt servicing.
An interrupt is acknowledged by the CPU while an instruction is being executed. However, no interrupt will be
The interrupt request non-sample instructions are as follows.
• EI instruction
• DI instruction
• LDSR reg2, 0x5 instruction (for PSW)
• The store instruction for the PRCMD register
• The store, SET1, NOT1, or CLR1 instructions for the following registers.
Restored PC is the value of the program counter (PC) saved to EIPC, FEPC, or DBPC when interrupt servicing
• Load instructions (SLD.B, SLD.BU, SLD.H, SLD.HU, SLD.W)
• Divide instructions (DIV, DIVH, DIVU, DIVHU)
• PREPARE, DISPOSE instructions (only when an interrupt occurs before the stack pointer is updated)
• Interrupt-related registers:
• Power save control register (PSC)
• On-chip debug mode register (OCDM)
Remarks 1. xx: Identification name of each peripheral unit (see Table 21-3 Interrupt Control Registers
Interrupt control register (xxICn), interrupt mask registers 0 to 3 (IMR0 to IMR3)
If a non-maskable or maskable interrupt is acknowledged during the execution of any of the following
2. For details about the operation of the pipeline, see the V850ES Architecture User's Manual
(U15943E).
n:
CHAPTER 21 INTERRUPT SERVICING/EXCEPTION PROCESSING FUNCTION
(xxICn))
Peripheral unit number (see Table 21-3 Interrupt Control Registers (xxICn)).
User’s Manual U18953EJ5V0UD
821