UPD70F3786GJ-GAE-AX Renesas Electronics America, UPD70F3786GJ-GAE-AX Datasheet - Page 1048

no-image

UPD70F3786GJ-GAE-AX

Manufacturer Part Number
UPD70F3786GJ-GAE-AX
Description
MCU 32BIT V850ES/JX3-E 144-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Er
Datasheet

Specifications of UPD70F3786GJ-GAE-AX

Core Processor
RISC
Core Size
32-Bit
Speed
50MHz
Connectivity
CAN, CSI, EBI/EMI, Ethernet, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
100
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
124K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
UPD70F3786GJ-GAE-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
1046
(5) Recovery from bus-off state
When the CAN module is in the bus-off state, the transmission pins (CTXD0) cut off from the CAN bus always
output the recessive level.
The CAN module recovers from the bus-off state in the following bus-off recovery sequence.
<1> Request to enter the CAN initialization mode
<2> Request to enter a CAN operation mode
(a) Recovery from bus-off state through normal recovery sequence
The CAN module first issues a request to enter the initialization mode (refer to timing <1> in Figure 21-17).
This request will be immediately acknowledged, and the C0CTRL.OPMODE2 to OPMODE0 bits are
cleared to 000B. Processing such as analyzing the fault that has caused the bus-off state, re-defining the
CAN module and message buffer using application software, or stopping the operation of the CAN module
can be performed by clearing the C0GMCTRL.GOM bit to 0.
Next, the module requests to change the mode from the initialization mode to an operation mode (refer to
timing <2> in Figure 21-17). This starts an operation to recover the CAN module from the bus-off state.
The conditions under which the module can recover from the bus-off state are defined by the CAN
protocol ISO 11898, and it is necessary to detect 11 consecutive recessive-level bits more than 128 times.
At this time, the request to change the mode to an operation mode is held pending until the recovery
conditions are satisfied. When the recovery conditions are satisfied (refer to timing <3> in Figure 21-17),
the CAN module can enter the operation mode it has requested. Until the CAN module enters this
operation mode, it stays in the initialization mode. Whether the CAN module has completed transition to
any other operation mode can be confirmed by reading the OPMODE2 to OPMODE0 bits.
transition to any other operation mode is completed, OPMODE2 to OPMODE0 bits = 000B is read.
During the bus-off period and bus-off recovery sequence, the C0INFO.BOFF bit stays set (to 1). In the
bus-off recovery sequence, the reception error counter (C0ERC.REC0 to C0ERC.REC6) counts the
number of times 11 consecutive recessive-level bits have been detected on the bus. Therefore, the
recovery state can be checked by reading the REC0 to REC6 bits.
Cautions 1. If a request to change the mode from the initialization mode to any operation mode
(a) Recovery operation through normal recovery sequence
(b) Forced recovery operation that skips recovery sequence
2. In the bus-off recovery sequence, the REC0 to REC6 bits counts up (+1) each time 11
to execute the bus-off recovery sequence again during a bus-off recovery sequence,
the bus-off recovery sequence starts from the beginning and 11 contiguous
recessive bits are counted 128 times again on the bus.
consecutive recessive-level bits have been detected. Even during the bus-off period,
the CAN module can enter the CAN sleep mode or CAN stop mode. To be released
from the bus-off state, the module must enter the initialization mode once. If the
module is in the CAN sleep mode or CAN stop mode, however, it cannot directly
enter the initialization mode. In this case, the bus off recovery sequence is started at
the same time as the CAN sleep mode is released even without shifting to the
initialization
C0CTRL.PSMODE0 bits by software, the bus off recovery sequence is also started
due to wakeup by dominant edge detection on the CAN bus (While the CAN clock is
supplied, the C0CTRL.PSMODE0 bit must be cleared by software after a dominant
edge is detected.) .
mode.