S1D13705 Epson Electronics America, Inc., S1D13705 Datasheet - Page 224

no-image

S1D13705

Manufacturer Part Number
S1D13705
Description
S1d13705 Embedded Memory Lcd Controller
Manufacturer
Epson Electronics America, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D1370500A1
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13705F00A100
Manufacturer:
EPSON
Quantity:
1 831
Part Number:
S1D13705F00A200
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Page 6
Scripting
Comments
S1D13705
X25A-B-005-03
13705PLAY can be driven by a script file. This is useful when:
• there is no standard display output to monitor command entry and results.
• various registers must be quickly changed faster than can achieved by typing.
• The same series of keystrokes is being entered time and again.
A script file is an ASCII text file with one 13705PLAY command per line. All scripts must
end with a “q” (quit) command in order to return control to the operating system. The semi-
colon is used as a comment delimitor. Everything on a line after the semi-colon will be
ignored.
On a PC platform, a typical script command line is: “13705PLAY < dumpregs.scr >
results”.
This causes the script file “dumpregs.scr” to be interpreted and the results to be sent to the
file “results.”
Example 1: The script file “dumpregs.scr” can be created with and text editor and will look
• All numeric values are considered to be hexadecimal unless identified otherwise. For
• Redirecting commands from a script file (PC platform) allows those commands to be
example, 10 = 10h = 16 decimal; 10t = 10 decimal; 010b = 2 decimal.
executed as though they were typed.
like the following:
; This file initializes the S1D13705 and reads the registers
i
xa
la
q
; Initialize the registers.
; Dump all the registers
; And the LUT
; Exit
Epson Research and Development
13705PLAY Diagnostic Utility
Vancouver Design Center
Issue Date: 01/02/12

Related parts for S1D13705