MC9S12G FREESCALE [Freescale Semiconductor, Inc], MC9S12G Datasheet - Page 782

no-image

MC9S12G

Manufacturer Part Number
MC9S12G
Description
Ignores external trigger. Performs one conversion sequence and stops.
Manufacturer
FREESCALE [Freescale Semiconductor, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12G128MLH
Manufacturer:
ROHM
Quantity:
1 200
Part Number:
MC9S12G128MLH
Manufacturer:
FREESCALE
Quantity:
1 500
Part Number:
MC9S12G128MLH
Manufacturer:
FREESCALE
Quantity:
1 500
Part Number:
MC9S12G128MLL
Manufacturer:
AVAGO
Quantity:
2 300
Part Number:
MC9S12G128MLL
Manufacturer:
FREESCALE
Quantity:
3 400
Part Number:
MC9S12G128MLL
Manufacturer:
FREESCALE
Quantity:
3 400
Part Number:
MC9S12G192CLL
Manufacturer:
FREESCALE
Quantity:
3 400
Part Number:
MC9S12GC128GFU2
Quantity:
69
Part Number:
MC9S12GC128MFUE
Manufacturer:
Freescale Semiconductor
Quantity:
135
48 KByte Flash Module (S12FTMRG48K1V1)
23.3.2.11 Flash Common Command Object Register (FCCOB)
The FCCOB is an array of six words addressed via the CCOBIX index found in the FCCOBIX register.
Byte wide reads and writes are allowed to the FCCOB register.
23.3.2.11.1 FCCOB - NVM Command Mode
NVM command mode uses the indexed FCCOB register to provide a command code and its relevant
parameters to the Memory Controller. The user first sets up all required FCCOB fields and then initiates
the command’s execution by writing a 1 to the CCIF bit in the FSTAT register (a 1 written by the user clears
the CCIF command completion flag to 0). When the user clears the CCIF bit in the FSTAT register all
FCCOB parameter fields are locked and cannot be changed by the user until the command completes (as
evidenced by the Memory Controller returning CCIF to 1). Some commands return information to the
FCCOB register array.
The generic format for the FCCOB parameter fields in NVM command mode is shown in
return values are available for reading after the CCIF flag in the FSTAT register has been returned to 1 by
the Memory Controller. Writes to the unimplemented parameter fields (CCOBIX = 110 and CCOBIX =
111) are ignored with reads from these fields returning 0x0000.
Table 23-24
contains the command code, followed by the parameters for this specific Flash command. For details on
the FCCOB settings required by each command, see the Flash command descriptions in
782
Offset Module Base + 0x000A
Offset Module Base + 0x000B
Reset
Reset
This document is valid for the S12G96 and the S12G128 device. All information related to other devices is preliminary.
W
W
R
R
shows the generic Flash command format. The high byte of the first word in the CCOB array
0
0
7
7
Figure 23-17. Flash Common Command Object Low Register (FCCOBLO)
Figure 23-16. Flash Common Command Object High Register (FCCOBHI)
CCOBIX[2:0]
000
001
Table 23-24. FCCOB - NVM Command Mode (Typical Usage)
0
0
6
6
MC9S12G Family Reference Manual,
Byte
LO
LO
HI
HI
5
0
5
0
FCCOB Parameter Fields (NVM Command Mode)
FCMD[7:0] defining Flash command
0
0
4
4
CCOB[15:8]
6’h0, Global address [17:16]
CCOB[7:0]
Global address [15:8]
Global address [7:0]
0
0
3
3
Rev.1.01
2
0
2
0
Freescale Semiconductor
0
0
1
1
Table
Section
23-24. The
23.4.6.
0
0
0
0

Related parts for MC9S12G