Specifications of EP4SE530H35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
744
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SE530H35C2N
Manufacturer:
ALTERA
Quantity:
147
Part Number:
EP4SE530H35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H35C2NES
Manufacturer:
ALTERA
0
5–36
Stratix IV Device Handbook Volume 1
Programmable Bandwidth
Stratix IV PLLs provide advanced control of the PLL bandwidth using the PLL loop’s
programmable characteristics, including loop filter and charge pump.
Background
PLL bandwidth is the measure of the PLL’s ability to track the input clock and its
associated jitter. The closed-loop gain 3 dB frequency in the PLL determines PLL
bandwidth. Bandwidth is approximately the unity gain point for open loop PLL
response. As
frequency. Stratix IV PLLs provide three bandwidth settings—low, medium (default),
and high.
Figure 5–32. Open- and Closed-Loop Response Bode Plots
Open-Loop Reponse Bode Plot
Closed-Loop Reponse Bode Plot
Gain
Gain
0 dB
Figure 5–32
shows, these points correspond to approximately the same
Chapter 5: Clock Networks and PLLs in Stratix IV Devices
Frequency
Frequency
Increasing the PLL's
bandwidth in effect pushes
the open loop response out.
February 2011 Altera Corporation
PLLs in Stratix IV Devices