EP4SE530H35C2N Altera, EP4SE530H35C2N Datasheet - Page 63

no-image

EP4SE530H35C2N

Manufacturer Part Number
EP4SE530H35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
STRATIX® IV Er

Specifications of EP4SE530H35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
744
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SE530H35C2N
Manufacturer:
ALTERA
Quantity:
147
Part Number:
EP4SE530H35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H35C2NES
Manufacturer:
ALTERA
0
Chapter 3: TriMatrix Embedded Memory Blocks in Stratix IV Devices
Overview
February 2011 Altera Corporation
Error Correction Code (ECC) Support
1
1
Stratix IV M144K blocks have built-in support for error correction code (ECC) when in
×64-wide simple dual-port mode. ECC allows you to detect and correct data errors in
the memory array. The M144K blocks have a single-error-correction
double-error-detection (SECDED) implementation. SECDED can detect and fix a
single bit error in a 64-bit word, or detect two bit errors in a 64-bit word. It cannot
detect three or more errors.
The M144K ECC status is communicated using a three-bit status flag
eccstatus[2..0]. The status flag can be either registered or unregistered. When
registered, it uses the same clock and asynchronous clear signals as the output
registers. When unregistered, it cannot be asynchronously cleared.
Table 3–3
Table 3–3. Truth Table for ECC Status Flags
You cannot use the byte enable feature when ECC is engaged.
Read-during-write “old data mode” is not supported when ECC is engaged.
No error
Single error and fixed
Double error and no fix
Illegal
Illegal
Illegal
Illegal
lists the truth table for the ECC status flags.
Status
eccstatus[2]
0
0
1
0
0
1
1
eccstatus[1]
0
1
0
0
1
0
1
Stratix IV Device Handbook Volume 1
eccstatus[0]
0
1
1
1
0
0
X
3–7