EP4SE530H35C2N Altera, EP4SE530H35C2N Datasheet - Page 797

no-image

EP4SE530H35C2N

Manufacturer Part Number
EP4SE530H35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
STRATIX® IV Er

Specifications of EP4SE530H35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
744
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SE530H35C2N
Manufacturer:
ALTERA
Quantity:
147
Part Number:
EP4SE530H35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H35C2NES
Manufacturer:
ALTERA
0
Chapter 3: Configuring Multiple Protocols and Data Rates in Stratix IV Devices
Combination Requirements When You Enable Channel Reconfiguration
February 2011 Altera Corporation
Example 12 shows the requirements.
Example 12
Consider that you intend to run four channels within the transceiver block to switch
between GIGE and SONET OC48 data rates. Assume that by default two channels run
at GIGE data rates and the other two channels run at SONET OC48 data rates.
Assume that Instance1 with two channels running at GIGE data rate is created with
the configuration, as listed in
Table 3–16. Combining Requirements with the Use Alternate CMU PLL Option Enabled—
Instance 1 for Example 12
Create Instance 2 with the following parameters to enable the Quartus II software to
share CMU PLLs between the two instances.
Table 3–17
Table 3–17. Combining Requirements with the Use Alternate CMU PLL Option Enabled—
Instance 2 for Example 12
Table 3–18
Instance 1 when you compile the design.
Table 3–18. Assignment for the GXB TX PLL Reconfiguration Group for Instance 1
To
Assignment Name
Value
Alternate PLL
Alternate PLL
Main PLL
Main PLL
Assignment
PLL
PLL
lists the required parameters to be set for Instance 2.
lists the assignment for the GXB TX PLL Reconfiguration group for
Data Rate (Gbps)
Data Rate (Gbps)
tx_dataout_instance1[0]
Note that the number of channels in this instance is 2. You can use any
one of the channel port names within this instance for this assignment.
GXB TX PLL Reconfiguration group setting
6
2.488
2.488
1.25
1.25
Table
3–16.
Input Reference Clock (MHz)
Input Reference Clock (MHz)
155.5
155.5
125
125
Stratix IV Device Handbook Volume 2: Transceivers
Setting
PLL Logical Reference
PLL Logical Reference
Index
Index
0
1
1
0
3–43