HD64F2676VFC33 Renesas Electronics America, HD64F2676VFC33 Datasheet - Page 752

IC H8S MCU FLASH 256K 144-QFP

HD64F2676VFC33

Manufacturer Part Number
HD64F2676VFC33
Description
IC H8S MCU FLASH 256K 144-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2676VFC33

Core Processor
H8S/2600
Core Size
16-Bit
Speed
33MHz
Connectivity
IrDA, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
103
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 4x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2676VFC33
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F2676VFC33
Quantity:
9 520
Part Number:
HD64F2676VFC33
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F2676VFC33V
Manufacturer:
ROHM
Quantity:
750 000
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS
Quantity:
120
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 15 Serial Communication Interface (SCI, IrDA)
Rev. 3.00 Mar 17, 2006 page 700 of 926
REJ09B0283-0300
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1?
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
Figure 15.9 Sample Serial Reception Data Flowchart (1)
All data received?
FER flags in SSR
Start of reception
Initialization
RDRF = 1?
<End>
Yes
Yes
No
(Continued on next page)
Error handling
Yes
[1]
[2]
[4]
[5]
[3]
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DMAC or DTC is
activated by an RXI interrupt and
the RDR value is read.
Receive error handling and