Z8FMC160100KITG Zilog, Z8FMC160100KITG Datasheet - Page 110

KIT DEV FOR Z8 ENCORE Z8FMC16100

Z8FMC160100KITG

Manufacturer Part Number
Z8FMC160100KITG
Description
KIT DEV FOR Z8 ENCORE Z8FMC16100
Manufacturer
Zilog
Series
Z8 Encore! MC™r

Specifications of Z8FMC160100KITG

Main Purpose
Power Management, Motor Control
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
Z8FMC16100
Primary Attributes
3-Ph DC Motors
Secondary Attributes
Graphical User Interface
For Use With
269-4664 - KIT ACC OPTO-ISO USB SMART CABLE269-4661 - KIT ACC ETHERNET SMART CABLE269-4539 - KIT ACCESSORY USB SMART CABLE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4660
PS024613-0910
the count value in the Timer High and Low Byte registers is reset to
resumes. If no capture event occurs, upon reaching the compare value, the timer generates
an interrupt, the count value in the Timer High and Low Byte registers is reset to
and counting resumes.
Follow the steps below to configure a timer for one of these capture modes and initiate the
count:
1. Write to the Timer Control registers to:
2. Write to the Timer High and Low Byte registers to set the starting count value
3. Write to the Timer Reload High and Low Byte registers to set the reload value.
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
5. Configure the associated GPIO port pin for the Timer Input alternate function.
6. Write to the Timer Control 1 register to enable the timer. In CAPTURE and
In capture modes, the elapsed time from a timer start to a capture event can be calculated
using the following equation (Start Value = 1):
COMPARE Mode
In COMPARE mode, the timer counts up to the 16-bit compare value stored in the Timer
Reload High and Low Byte registers. After reaching the compare value, the timer
generates an interrupt and counting continues (the timer value is not reset to
Timer Output alternate function is enabled, the Timer Output pin changes state (from Low
to High or High to Low).
If the timer reaches
Capture Elapsed Time (s) =
(a) Disable the timer.
(b) Configure the timer for the selected capture mode.
(c) Set the prescale value.
(d) Set the capture edge (rising or falling) for the Timer Input.
(e) Configure the timer interrupt to be generated at the input capture event, the reload
(typically
to the relevant interrupt registers.
CAPTURE RESTART modes, the timer begins counting. In CAPTURE COMPARE
mode, the timer does not start counting until the first input transition occurs.
event, or both, by setting the
0001h
FFFFh
).
, the timer rolls over to
(Capture Value – Start Value +1) x Prescale
TICONFIG
System Clock Frequency (Hz)
field.
0000h
Z8FMC16100 Series Flash MCU
and continues counting.
Product Specification
Timer Operating Modes
0001h
, and counting
0001h
0001h
). If the
,
98

Related parts for Z8FMC160100KITG