EP2AGX65DF29I5N Altera, EP2AGX65DF29I5N Datasheet - Page 224

no-image

EP2AGX65DF29I5N

Manufacturer Part Number
EP2AGX65DF29I5N
Description
IC ARRIA II GX FPGA 65K 780FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX65DF29I5N

Number Of Logic Elements/cells
60214
Number Of Labs/clbs
2530
Total Ram Bits
5246
Number Of I /o
364
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX65DF29I5N
Manufacturer:
ALTERA31
Quantity:
199
Part Number:
EP2AGX65DF29I5N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX65DF29I5N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX65DF29I5N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
EP2AGX65DF29I5N
Quantity:
130
7–28
Arria II Device Handbook Volume 1: Device Interfaces and Integration
1
1
For Arria II GZ devices, each bank can use settings from either or both adjacent DLLs
the bank. For example, DQS1L can get its phase-shift settings from DLL0, while DQS2L
can get its phase-shift settings from DLL1.
If you have a dedicated PLL that only generates the DLL input reference clock, set the
PLL mode to No Compensation or the Quartus II software automatically changes it.
Because the PLL does not use any other outputs, it does not have to compensate for
any clock paths.
Arria II devices support PLL cascading. If you cascade PLLs, you must use PLLs
adjacent to each other (for example, PLL5 and PLL6 for Arria II GX devices) so that
the dedicated path between the two PLLs is used instead of using a global clock
(GCLK) or regional clock (RCLK) network that might be subjected to core noise. The
TimeQuest Timing Analyzer takes PLL cascading into consideration for timing
analysis.
Table 7–5
Table 7–5. DLL Location and Supported I/O Banks for Arria II GZ Devices
Table 7–6
dedicated clock input pins for Arria II GX devices.
Table 7–6. DLL Reference Clock Input for Arria II GX Devices
DLL0
DLL1
DLL2
DLL3
Note to
(1) The DLL can access these I/O banks if they are available for memory interfacing.
DLL0
DLL1
Note to
(1) CLK4 to CLK7 are located on the bottom side, CLK8 to CLK11 are located on the right side, and CLK12 to CLK15
DLL
are located on the top side of the device.
Table
Table
DLL
lists the reference clock for each DLL might come from PLL output clocks or
lists the DLL location and supported I/O banks for Arria II GZ devices.
7–5:
7–6:
Bottom-right corner
Bottom-left corner
Top-right corner
Top-left corner
Location
(Top/Bottom)
CLK12
CLK13
CLK14
CLK15
CLKIN
CLK4
CLK5
CLK6
CLK7
1A, 1B, 1C, 2A, 2B, 2C, 7A, 7B, 7C, 8A, 8B, 8C
1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C
3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C
5A, 5B, 5C, 6A, 6B, 6C, 7A, 7B, 7C, 8A, 8B, 8C
Chapter 7: External Memory Interfaces in Arria II Devices
Accessible I/O Banks
(Right)
CLKIN
CLK10
CLK11
CLK8
CLK9
Arria II External Memory Interface Features
(Note 1)
December 2010 Altera Corporation
(1)
PLL1
PLL3
PLL

Related parts for EP2AGX65DF29I5N