MPC8533EVTARJ Freescale Semiconductor, MPC8533EVTARJ Datasheet - Page 534

no-image

MPC8533EVTARJ

Manufacturer Part Number
MPC8533EVTARJ
Description
MPU POWERQUICC 783-PBGA
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MPC8533EVTARJ

Processor Type
MPC85xx PowerQUICC III 32-Bit
Speed
1.067GHz
Voltage
1V
Mounting Type
Surface Mount
Package / Case
783-FCPBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC8533EVTARJ
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC8533EVTARJA
Manufacturer:
FREESCAL
Quantity:
156
Part Number:
MPC8533EVTARJA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Security Engine (SEC) 2.1
especially during processing, are likely to return non-zero values for many bits between 0–57. The four
signals shown are those which are most likely to be of interest to the user.
The MDEU status register is read-only. Writing to this location results in address error being reflected in
the MDEU interrupt status register.
Table 12-31
12-56
59–60
Address MDEU 0x3_6028
0–57
Bits
58
61
62
63
Reset
W
R
Name
HALT
ICCR
0
RD
IE
ID
describes the MDEU status register fields.
MPC8533E PowerQUICC III Integrated Host Processor Family Reference Manual, Rev. 1
Reserved
0 MDEU not halted
1 MDEU halted
Note: Because the error causing the MDEU to stop operating may be masked before reaching the interrupt
status register, the MDEU interrupt status register is used to provide a second source of information regarding
errors preventing normal operation.
Integrity check comparison result
00 No integrity check comparison was performed.
01 The integrity check comparison passed.
10 The integrity check comparison failed.
11 Reserved
Note: A passed or failed result is generated only if ICV checking is enabled.
Interrupt error. This status bit reflects the state of the ERROR interrupt signal, as sampled by the controller
interrupt status register
0 MDEU is not signaling error
1 MDEU is signaling error
Interrupt done. This status bit reflects the state of the DONE interrupt signal, as sampled by the controller
interrupt status register
0 MDEU is not signaling done
1 MDEU is signaling done
in the signal sampled by the appropriate channel.
0 Reset in progress
1 Reset done
Note: Reset done resets to 0, but has typically switched to 1 by the time a user checks the register, indicating
the EU is ready for operation.
Halt. Indicates that the MDEU has halted due to an error.
Reset done. This status bit, when high, indicates that MDEU has completed its reset sequence, as reflected
Table 12-31. MDEU Status Register Field Descriptions
Figure 12-34. MDEU Status Register
(Section 12.6.5.3, “Interrupt Status Register
(Section 12.6.5.3, “Interrupt Status Register
All zeros
Description
(ISR)”).
(ISR)”).
57
Freescale Semiconductor
HALT ICCR IE ID RD
58
Access: Read-only
59 60 61 62
63

Related parts for MPC8533EVTARJ