OM13013,598 NXP Semiconductors, OM13013,598 Datasheet - Page 210

no-image

OM13013,598

Manufacturer Part Number
OM13013,598
Description
BOARD DEMO IAR LPC1227 JLINKLITE
Manufacturer
NXP Semiconductors
Series
-r
Datasheets

Specifications of OM13013,598

Design Resources
LPC122x-SK Brd Schematic
Processor To Be Evaluated
LPC1227
Processor Series
LPC122x
Data Bus Width
32 bit
Interface Type
UART, SSP, SPI, I2C
Cpu Core
ARM Cortex-M0
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
3 V to 3.6 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-6885
NXP Semiconductors
Table 201. Slave Receiver mode
UM10441
User manual
STAT
Status
Code
0x98
0xA0
Status of the I
and hardware
Previously addressed
with General Call; DATA
byte has been received;
NOT ACK has been
returned.
A STOP condition or
repeated START
condition has been
received while still
addressed as Slave
Receiver or Slave
Transmitter.
2
C-bus
Application software response
To/From DAT
Read data byte
or
Read data byte
or
Read data byte
or
Read data byte
No STDAT
action or
No STDAT
action or
No STDAT
action or
No STDAT
action
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 15 February 2011
To CON
STA STO SI
0
0
1
1
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AA
0
1
0
1
0
1
0
1
Chapter 11: LPC122x I2C-bus controller
Next action taken by I
Switched to not addressed SLV mode; no
recognition of own SLA or General Call
address.
Switched to not addressed SLV mode;
Own SLA will be recognized; General Call
address will be recognized if
ADR[0] = logic 1.
Switched to not addressed SLV mode; no
recognition of own SLA or General Call
address. A START condition will be
transmitted when the bus becomes free.
Switched to not addressed SLV mode;
Own SLA will be recognized; General Call
address will be recognized if
ADR[0] = logic 1. A START condition will
be transmitted when the bus becomes
free.
Switched to not addressed SLV mode; no
recognition of own SLA or General Call
address.
Switched to not addressed SLV mode;
Own SLA will be recognized; General Call
address will be recognized if
ADR[0] = logic 1.
Switched to not addressed SLV mode; no
recognition of own SLA or General Call
address. A START condition will be
transmitted when the bus becomes free.
Switched to not addressed SLV mode;
Own SLA will be recognized; General Call
address will be recognized if
ADR[0] = logic 1. A START condition will
be transmitted when the bus becomes
free.
UM10441
2
© NXP B.V. 2011. All rights reserved.
C hardware
210 of 442