OM13013,598 NXP Semiconductors, OM13013,598 Datasheet - Page 214

no-image

OM13013,598

Manufacturer Part Number
OM13013,598
Description
BOARD DEMO IAR LPC1227 JLINKLITE
Manufacturer
NXP Semiconductors
Series
-r
Datasheets

Specifications of OM13013,598

Design Resources
LPC122x-SK Brd Schematic
Processor To Be Evaluated
LPC1227
Processor Series
LPC122x
Data Bus Width
32 bit
Interface Type
UART, SSP, SPI, I2C
Cpu Core
ARM Cortex-M0
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
3 V to 3.6 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-6885
NXP Semiconductors
UM10441
User manual
11.10.7.4 I
11.10.7.5 Bus error
An I
the bus. If the SCL line is obstructed (pulled LOW) by a device on the bus, no further serial
transfer is possible, and the problem must be resolved by the device that is pulling the
SCL bus line LOW.
Typically, the SDA line may be obstructed by another device on the bus that has become
out of synchronization with the current bus master by either missing a clock, or by sensing
a noise pulse as a clock. In this case, the problem can be solved by transmitting additional
clock pulses on the SCL line
time-out timer to detect an obstructed bus, but this can be implemented using another
timer in the system. When detected, software can force clocks (up to 9 may be required)
on SCL until SDA is released by the offending device. At that point, the slave may still be
out of synchronization, so a START should be generated to insure that all I
are synchronized.
A bus error occurs when a START or STOP condition is detected at an illegal position in
the format frame. Examples of illegal positions are during the serial transfer of an address
byte, a data bit, or an acknowledge bit.
2
Fig 27. Forced access to a busy I
Fig 28. Recovering from a bus obstruction caused by a LOW level on SDA
C-bus obstructed by a LOW level on SCL or SDA
2
C-bus hang-up can occur if either the SDA or SCL line is held LOW by any device on
(1) Unsuccessful attempt to send a START condition.
(2) SDA line is released.
(3) Successful attempt to send a START condition. State 08H is entered.
STO flag
SDA line
STA flag
SCL line
STA flag
SDA line
SCL line
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 15 February 2011
(1)
Figure
time limit
2
C-bus
28. The I
(1)
2
C interface does not include a dedicated
Chapter 11: LPC122x I2C-bus controller
(2)
condition
(3)
start
condition
start
UM10441
© NXP B.V. 2011. All rights reserved.
2
C peripherals
214 of 442