UPD78F0890GK(A)-GAJ-AX NEC, UPD78F0890GK(A)-GAJ-AX Datasheet - Page 577

8BIT MCU, 128K FLASH, 7K RAM, LQFP

UPD78F0890GK(A)-GAJ-AX

Manufacturer Part Number
UPD78F0890GK(A)-GAJ-AX
Description
8BIT MCU, 128K FLASH, 7K RAM, LQFP
Manufacturer
NEC
Datasheet

Specifications of UPD78F0890GK(A)-GAJ-AX

Controller Family/series
UPD78F
No. Of I/o's
55
Ram Memory Size
7KB
Cpu Speed
20MHz
No. Of Timers
10
No. Of Pwm
RoHS Compliant
Core Size
8bit
Program Memory Size
128KB
Oscillator Type
External, Internal
22.1 Functions of Low-Voltage Detector
pin is more than or less than the detection level can be checked by reading the low-voltage detection flag (LVIF: bit 0
of LVIM).
reset occurs. For details of RESF, see CHAPTER 19 RESET FUNCTION.
Selects reset (LVIMD = 1).
Generates an internal reset
signal when V
releases the reset signal when
V
DD
The low-voltage detector (LVI) has the following functions.
• The LVI circuit compares the supply voltage (V
• The supply voltage (V
• Reset or interrupt function can be selected by software.
• Detection levels (16 levels) of supply voltage can be changed by software.
• Operable in STOP mode.
The reset and interrupt signals are generated as follows depending on selection by software.
Remark LVISEL: Bit 2 of low-voltage detection register (LVIM)
While the low-voltage detector is operating, whether the supply voltage or the input voltage from an external input
When the low-voltage detector is used to reset, bit 0 (LVIRF) of the reset control flag register (RESF) is set to 1 if
≥ V
external input pin (EXLVI) with the detection voltage (V
reset or internal interrupt signal.
Selection of Level Detection of Supply Voltage (V
LVI
.
DD
LVIMD: Bit 1 of LVIM
< V
LVI
and
(LVISEL = 0)
DD
) or input voltage from an external input pin (EXLVI) can be selected by software.
Selects interrupt (LVIMD = 0).
Generates an internal interrupt
signal when V
than V
V
(V
DD
DD
CHAPTER 22 LOW-VOLTAGE DETECTOR
becomes V
≥ V
LVI
LVI
(V
).
DD
DD
< V
LVI
drops lower
User’s Manual U17554EJ4V0UD
LVI
or higher
) or when
DD
)
DD
) with the detection voltage (V
Selects reset (LVIMD = 1).
Generates an internal reset
signal when EXLVI < V
and releases the reset signal
when EXLVI ≥ V
EXLVI
= 1.21 V (TYP.): fixed), and generates an internal
Selection Level Detection of Input Voltage from
External Input Pin (EXLVI) (LVISEL = 1)
EXLVI
.
EXLVI
LVI
) or the input voltage from an
Selects interrupt (LVIMD = 0).
Generates an internal interrupt
signal when EXLVI drops
lower than V
V
becomes V
(EXLVI ≥ V
EXLVI
) or when EXLVI
EXLVI
EXLVI
EXLVI
).
or higher
(EXLVI <
577

Related parts for UPD78F0890GK(A)-GAJ-AX