EP3C25F324I7 Altera, EP3C25F324I7 Datasheet - Page 272

IC CYCLONE III FPGA 25K 324 FBGA

EP3C25F324I7

Manufacturer Part Number
EP3C25F324I7
Description
IC CYCLONE III FPGA 25K 324 FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C25F324I7

Number Of Logic Elements/cells
24624
Number Of Labs/clbs
1539
Total Ram Bits
608256
Number Of I /o
215
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
324-FBGA
Family Name
Cyclone III
Number Of Logic Blocks/elements
24624
# I/os (max)
215
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
24624
Ram Bits
608256
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
324
Package Type
FBGA
For Use With
544-2370 - KIT STARTER CYCLONE III EP3C25
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C25F324I7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25F324I7
Manufacturer:
ALTERA
0
Part Number:
EP3C25F324I7
0
Part Number:
EP3C25F324I7N
Manufacturer:
ALTERA32
Quantity:
181
Part Number:
EP3C25F324I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25F324I7N
Manufacturer:
XILINX
0
Part Number:
EP3C25F324I7N
Manufacturer:
ALTERA
0
Part Number:
EP3C25F324I7N
0
12–6
Guidelines for IEEE Std. 1149.1 BST
Cyclone III Device Handbook, Volume 1
Figure 12–1
inserted in the chain.
Figure 12–1. JTAG Chain of Mixed Voltages
Use the following guidelines when performing BST with IEEE Std. 1149.1 devices:
If the 10 bit checkerboard pattern (1010101010) does not shift out of the instruction
register via the TDO pin during the first clock cycle of the SHIFT_IR state, the TAP
controller did not reach the proper state. To solve this problem, try one of the
following procedures:
Perform a SAMPLE/PRELOAD test cycle prior to the first EXTEST test cycle to
ensure that known data is present at the device pins when you enter the EXTEST
mode. If the OEJ update register contains a 0, the data in the OUTJ update register
is driven out. The state must be known and correct to avoid contention with other
devices in the system.
Do not perform EXTEST testing during ICR. This instruction is supported before
or after ICR, but not during ICR. Use the CONFIG_IO instruction to interrupt
configuration and then perform testing, or wait for configuration to complete.
If testing is performed before configuration, hold the nCONFIG pin low.
Verify that the TAP controller has reached the SHIFT_IR state correctly. To
advance the TAP controller to the SHIFT_IR state, return to the RESET state
and send the code 01100 to the TMS pin.
Check the connections to the VCC, GND, JTAG, and dedicated configuration
pins on the device.
shows the JTAG chain of mixed voltages and how a level shifter is
Tester
TDO
TDI
tester if necessary
level accepted by
Shift TDO to
Shifter
Chapter 12: IEEE 1149.1 (JTAG) Boundary-Scan Testing for the Cyclone III Device Family
Level
V
3.3 V
CCIO
Must be
tolerant
V
1.5 V
1.8 V
CCIO
Must be
tolerant
V
2.5 V
3.3 V
CCIO
© December 2009 Altera Corporation
Guidelines for IEEE Std. 1149.1 BST
Must be
tolerant
V
1.8 V
2.5 V
CCIO

Related parts for EP3C25F324I7