UPD70F3771GF-GAT-AX Renesas Electronics America, UPD70F3771GF-GAT-AX Datasheet - Page 1052

no-image

UPD70F3771GF-GAT-AX

Manufacturer Part Number
UPD70F3771GF-GAT-AX
Description
MCU 32BIT V850ES/JX3-H 128-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Hr
Datasheet

Specifications of UPD70F3771GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CAN, CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3771GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-H, V850ES/JH3-H
R01UH0042EJ0400 Rev.4.00
Sep 30, 2010
Notes 3. The SET_FEATURE request sets the UF0 device status register L (UF0DSTL) and UF0 EPn status register L
Cautions 1. The sequence of control transfer defined by the Universal Serial Bus Specification is not satisfied
Remarks 1. Df: Default state, Ad: Addressed state, Cf: Configured state
4. If the wValue is not the default value, an automatic STALL response is made.
2. An ACK response is made even when the host transmits data other than a Null packet in the
3. If the wLength value is 00H during control transfer (read) of FW processing, a Null packet is
2. n = 0 to 4
3. $$: Valid endpoint number including transfer direction
4. ? and #: Value transmitted from host (information on Interface numbers 0 to 4)
(UF0EnSL) (n = 0 to 4, 7) when ACK is received in the status stage. If the E0HALT bit of the UF0E0SL
register is set, a STALL response is made in the status stage or data stage of control transfer for a request
other than the GET_STATUS Endpoint0 request, SET_FEATURE Endpoint0 request, and a request
generated by the CPUDEC interrupt request, until the CLEAR_FEATURE Endpoint0 request is received. A
STALL response to an unsupported request does not set the E0HALT bit of the UF0E0SL register to 1, and
the STALL response is cleared as soon as the next SETUP token has been received.
under the following conditions. The operation is not guaranteed under these conditions.
• If an IN/OUT token is suddenly received without a SETUP stage
• If DATA PID1 is sent in the data phase of the SETUP stage
• If a token of 128 addresses or more is received
• If the request data transmitted in the SETUP stage is of less than 8 bytes
status stage.
automatically transmitted for control transfer (without data).
automatically transmit a Null packet.
It is determined by the setting of the UF0 active interface number register (UF0AIFN) whether a request
with Interface number 1 to 4 is correctly responded to, depending on whether the Interface number of the
target is valid or not.
The valid endpoint is determined by the currently set Alternate Setting number (see 21.6.3 (36) UF0
active alternative setting register (UF0AAS), (38)
(UF0E1IM) to (42) UF0 endpoint 7 interface mapping register (UF0E7IM)).
It is determined by the UF0 active interface number register (UF0AIFN) and UF0 active alternative setting
register (UF0AAS) whether an Alternate Setting request corresponding to each Interface number is
correctly responded to or not, depending on whether the Interface number and Alternate Setting of the
target are valid or not.
CHAPTER 21 USB FUNCTION CONTROLLER (USBF)
UF0 endpoint 1 interface mapping register
The FW request does not
Page 1052 of 1509