Specifications of UPD70F3771GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CAN, CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3771GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-H, V850ES/JH3-H
positive error faster than 32.768 kHz occurs at the resonator. Similarly, if a negative error slower than 32.768 kHz occurs
at the resonator, the watch can be accurately counted by decrementing the RC1SUBC count value.
RC1SUBC value.
R01UH0042EJ0400 Rev.4.00
Sep 30, 2010
As shown in Figure 12-10, the watch can be accurately counted by incrementing the RC1SUBC count value, if a
The RC1SUBC correction value is determined by using the RC1SUBU.F6 to RC1SUBU.F0 bits.
The F6 bit is used to determine whether to increment or decrement RC1SUBC and the F5 to F0 bits to determine the
(1) Incrementing the RC1SUBC count value
(2) Decrementing the RC1SUBC count value
The RC1SUBC count value is incremented by the value set using the F5 to F0 bits, by setting the F6 bit to 0.
Expression for calculating the increment value: (F5 to F0 bit value − 1) × 2
[Example of incrementing the RC1SUBC count value: F6 bit = 0]
The RC1SUBC count value is decremented by an inverted value of the value set using the F5 to F0 bits, by setting
the F6 bit to 1.
Expression for calculating the decrement value: (Inverted value of F5 to F0 bit value + 1) × 2
[Example of decrementing the RC1SUBC count value: F6 bit = 1]
If 15H (010101B) is set to the F5 to F0 bits
RC1SUBC count value = 32,768 + 40 = 32,808
If 15H (010101B) is set to the F5 to F0 bits
RC1SUBC count value = 32,768 − 86 = 32,682
(15H − 1) × 2 = 40 (increments the RC1SUBC count value by 40)
Inverted data of 15H (010101B) = 2AH (101010B)
(2AH + 1) × 2 = 86 (decrements the RC1SUBC count value by 86)