cx28224 Mindspeed Technologies, cx28224 Datasheet - Page 263

no-image

cx28224

Manufacturer Part Number
cx28224
Description
Cx28224/5/9 Inverse Multiplexing For The Atm Ima Family
Manufacturer
Mindspeed Technologies
Datasheet
CX28224/5/9 Data Sheet
Table A-8. IMA Interface OAM Operation Functions (3 of 5)
28229-DSH-001-D
OAM.31 Does the implementation increment Rx-UUS-IMA for each second
OAM.32 Does the implementation increment Tx-UUS-IMA-FE for each
OAM.33 Does the implementation increment Rx-UUS-IMA-FE for each
OAM.34 Does the implementation increment Tx-FC each time the Tx-Mis-
OAM.35 Does the implementation increment Tx-FC each time the Tx-Fault
OAM.36 Does the implementation increment Rx-FC each time the LIF link
OAM.37 Does the implementation increment Rx-FC each time the LODS link
OAM.38 Does the implementation increment Rx-FC each time the Rx-Mis-
OAM.39 Does the implementation increment Rx-FC each time the Rx-Fault
OAM.40 Does the implementation increment Tx-FC-FE each time the Tx-
OAM.41 Does the implementation increment Rx-FC-FE each time the RFI-
OAM.42 Does the implementation increment Rx-FC-FE each time the Rx-
OAM.43 Does the implementation increment Tx-Stuff-IMA for each stuff
OAM.44 Does the implementation increment Rx-Stuff-IMA for each stuff
OAM.45 Does the implementation increment GR-UAS-IMA for each second
Item
when the NE Rx LSM is Unusable, as indicated in Table 19 on page
77?
second when the FE Tx LSM is reported Unusable, as indicated in
Table 19 on page 77?
second when the FE Rx LSM is reported Unusable, as indicated in
Table 19 on page 77?
Connected link failure condition is entered, as indicated in Table 19
on page 77?
link failure condition is entered, as indicated in Table 19 on page
77?
failure condition is entered, as indicated in Table 19 on page 77?
failure condition is entered, as indicated in Table 19 on page 77?
Connected link failure condition is entered, as indicated in Table 19
on page 77?
link failure condition is entered, as indicated in Table 19 on page
77?
Unusable-FE link failure condition is entered, as indicated in Table
19 on page 77?
IMA link failure condition is entered, as indicated in Table 19 on
page 77?
Unusable-FE link failure condition is entered, as indicated in Table
19 on page 77?
event inserted in the transmit direction, as indicated in Table 19 on
page 77?
event detected in the receive direction, except during seconds
when a SES-IMA or UAS-IMA condition is reported, as indicated in
Table 19 on page 77?
when the GTSM is down, as indicated in Table 19 on page 77?
Protocol feature
Mindspeed Technologies
Cond. for
Status
Status
Pred.
M
M
M
M
M
M
M
M
M
M
O
O
O
O
O
IMA Version 1.1 PICS Proforma
(R-131)
(R-132)
(R-133)
(R-134)
(R-134)
(R-135)
(R-135)
(R-135)
(R-135)
(O-21)
(O-22)
(O-22)
(O-23)
(O-24)
(R-136)
Ref.
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Yes X No__
Support