SC2200 NSC [National Semiconductor], SC2200 Datasheet - Page 215

no-image

SC2200

Manufacturer Part Number
SC2200
Description
Thin Client On a Chip
Manufacturer
NSC [National Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC2200A-00
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
SC2200A-00A00
Manufacturer:
MAXIM
Quantity:
15
Part Number:
SC2200A-00A00E
0
Part Number:
SC2200UCL-26
Manufacturer:
ALTERA
0
Part Number:
SC2200UCL-266
Manufacturer:
NSC
Quantity:
5 510
Part Number:
SC2200UCL-266
Manufacturer:
AMD
Quantity:
648
Part Number:
SC2200UCL-266
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
SC2200UCL-266 D2
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
SC2200UFH-266
Manufacturer:
SIERRA
Quantity:
1 238
Part Number:
SC2200UFH-266
Manufacturer:
AMD
Quantity:
996
Part Number:
SC2200UFH-266
Manufacturer:
NS/国半
Quantity:
20 000
Revision 3.0
Core Logic Module
Table 5-29. F0: PCI Header and Bridge Configuration Registers for GPIO and LPC Support (Continued)
Index 84h
The bits in this register are used for the second level of status reporting. The top level is reported at F1BAR0+I/O Offset 00h/02h[0].
This register is called a "mirror" register since an identical register exists at F0 Index F4h. Reading this register does not clear the status,
while reading its counterpart at F0 Index F4h clears the status at both the second and the top levels.
Index 85h
The bits in this register contain second level status reporting. Top level status is reported in F1BAR0+I/O Offset 00h/02h[0].
This register is called a “Mirror” register since an identical register exists at F0 Index F5h. Reading this register does not clear the status,
while reading its counterpart at F0 Index F5h clears the status at both the second and top levels.
7:3
Bit
0
2
1
0
7
6
5
Description
General Purpose Timer 1 Enable. Turn on GP Timer 1 Count Register (F0 Index 88h) and generate an SMI when the timer
expires.
0: Disable.
1: Enable.
This idle timer’s load is multi-sourced and gets reloaded any time an enabled event (F0 Index 89h[6:0]) occurs.
GP Timer 1 programming is at F0 Index 8Bh[4].
Top level SMI status is reported at F1BAR0+I/O Offset 00h/02h[9].
Second level SMI status is reported at F1BAR0+I/O Offset 04h/06h[0].
Reserved. Reads as 0.
GPWIO2 SMI Status. Indicates whether or not an SMI was caused by a transition on the GPWIO2 pin.
0: No.
1: Yes.
To enable SMI generation:
1) Ensure that GPWIO2 is enabled as an input: F1BAR1+I/O Offset 15h[2] = 0.
2) Set F1BAR1+I/O Offset 15h[6] to 1.
GPWIO1 SMI Status. Indicates whether or not an SMI was caused by a transition on the GPWIO1 pin.
0: No.
1: Yes.
To enable SMI generation:
1) Ensure that GPWIO1 is enabled as an input: F1BAR1+I/O Offset 15h[1] = 0.
2) Set F1BAR1+I/O Offset 15h[5] to 1.
GPWIO0 SMI Status. Indicates whether or not an SMI was caused by a transition on the GPWIO0 pin.
0: No.
1: Yes.
To enable SMI generation:
1) Ensure that GPWIO0 is enabled as an input: F1BAR1+I/O Offset 15h[0] = 0.
2) Set F1BAR1+I/O Offset 15h[4] to 1.
Video Idle Timer Timeout. Indicates whether or not an SMI was caused by expiration of Video Idle Timer Count Register
(F0 Index A6h).
0: No.
1: Yes.
To enable SMI generation, set F0 Index 81h[7] to 1.
User Defined Device Idle Timer 3 Timeout. Indicates whether or not an SMI was caused by expiration of User Defined
Device 3 Idle Timer Count Register (F0 Index A4h).
0: No
1: Yes
To enable SMI generation, set F0 Index 81h[6] to 1.
User Defined Device Idle Timer 2 Timeout. Indicates whether or not an SMI was caused by expiration of User Defined
Device 2 Idle Timer Count Register (F0 Index A2h).
0: No.
1: Yes.
To enable SMI generation, set F0 Index 81h[5] to 1.
(Continued)
Second Level PME/SMI Status Mirror Register 1 (RO)
Second Level PME/SMI Status Mirror Register 2 (RO)
215
Reset Value: 00h
Reset Value: 00h