EP4SGX530HH35C2N Altera, EP4SGX530HH35C2N Datasheet - Page 63

IC STRATIX IV FPGA 530K 1152HBGA

EP4SGX530HH35C2N

Manufacturer Part Number
EP4SGX530HH35C2N
Description
IC STRATIX IV FPGA 530K 1152HBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX530HH35C2N

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
564
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-HBGA
Family Name
Stratix® IV
Number Of Logic Blocks/elements
531200
# Registers
424960
# I/os (max)
560
Process Technology
40nm
Operating Supply Voltage (typ)
900mV
Logic Cells
531200
Ram Bits
28033024
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FCHBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX530HH35C2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX530HH35C2N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAD
Manufacturer:
ALTERA
0
Part Number:
EP4SGX530HH35C2NAE
Manufacturer:
ALTERA
0
Chapter 3: TriMatrix Embedded Memory Blocks in Stratix IV Devices
Overview
February 2011 Altera Corporation
Error Correction Code (ECC) Support
1
1
Stratix IV M144K blocks have built-in support for error correction code (ECC) when in
×64-wide simple dual-port mode. ECC allows you to detect and correct data errors in
the memory array. The M144K blocks have a single-error-correction
double-error-detection (SECDED) implementation. SECDED can detect and fix a
single bit error in a 64-bit word, or detect two bit errors in a 64-bit word. It cannot
detect three or more errors.
The M144K ECC status is communicated using a three-bit status flag
eccstatus[2..0]. The status flag can be either registered or unregistered. When
registered, it uses the same clock and asynchronous clear signals as the output
registers. When unregistered, it cannot be asynchronously cleared.
Table 3–3
Table 3–3. Truth Table for ECC Status Flags
You cannot use the byte enable feature when ECC is engaged.
Read-during-write “old data mode” is not supported when ECC is engaged.
No error
Single error and fixed
Double error and no fix
Illegal
Illegal
Illegal
Illegal
lists the truth table for the ECC status flags.
Status
eccstatus[2]
0
0
1
0
0
1
1
eccstatus[1]
0
1
0
0
1
0
1
Stratix IV Device Handbook Volume 1
eccstatus[0]
0
1
1
1
0
0
X
3–7