TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 52

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Boot
ROM
RAM
1st byte
2nd byte
3rd byte
6th byte
7th byte
8th byte
9th byte
10th byte
(n − 4)th byte
(n − 3)th byte
(n − 2)th byte
(n − 1)th byte
n’th byte
Byte Number to
to
to
Transfer
Note: The built-in PLL (clock multiplier) is not used regardless of the oscillation frequency.
(3) UART data transfer format
“Error code x 3” means that the error code is transmitted three times. For example, if the error code is 62H, the
TMP92CF26A transmits 62H three times. For error codes, see (4)-b).
Table 3.4.6 to Table 3.4.11 show the supported frequencies, data transfer format, baud
rate modification command, operation command, and version management
information, respectively.
Please also refer to the description of boot program operation later in this section.
Matching data (5AH)
Baud rate modification command
User program
Intel Hex format (binary)
User program start command (C0H)
(See Table 3.4.9.)
Branch to user program start address
(See Table 3.4.8.)
Transfer data from PC to TMP92CF26A
6.00 MHz
Table 3.4.6 Supported Frequencies (X1)
Table 3.4.7 Transfer Format
8.00 MHz
92CF26A-51
9600 bps
9.00 MHz
New baud rate
Baud Rate
− (Frequency measurement and baud
rate auto setting)
OK: Echo back data (5AH)
Error: No transfer
Version management information
(See Table 3.4.10)
Frequency information
OK: Echo back data
Error: Error code x 3
NG: Operation stop by checksum error
OK: SUM (High)
(See (4)-c).)
OK: SUM (Low)
OK: Echo back data (C0H)
Error: Error code x 3
10.00 MHz
Transfer data from TMP92CF26A to PC
TMP92CF26A
2007-11-21

Related parts for TMP92CF26AXBG