TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 53

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Modification Command
Baud Rate (bps)
Note 1: If f
Note 2: If f
(4) Description of the UART boot program operation
size is 124 Kbytes (3000H – 21FFFH). (The extended Intel Hex format is supported.)
a)
it to the internal RAM. If the transfer ends normally, the boot program calculates
SUM and sends the result to the PC before executing the user program. The execution
start address is the first address received. The boot program enables users to perform
customized on-board programming.
The boot program receives a user program sent from the PC via UART and transfers
When UART is used to download a user program, the maximum allowed program
OSCH
OSCH
1. Connect the serial cable. This must be done before the microcontroller is reset.
2. Set the AM1 and AM0 pins to “1” and reset the microcontroller.
3. The receive data in the 1st byte is matching data (5AH). Upon starting in
4. The 2nd byte is used to echo back 5AH to the PC upon completion of the
5. The 3rd through 6th bytes are used to send the version management
6. The 7th byte is used to send information on the measured frequency. The PC
Operation procedure
(oscillation frequency) is 10.0 MHz, 57600 and 115200 bps are not supported.
(oscillation frequency) is 6.00, 8.00, or 9.00 MHz, 38400, 57600, and 115200 bps are not supported.
Operation Command
X1-X2 oscillator
Version Information
BOOT mode, the boot program goes to a state in which it waits for matching
data. When matching data is received, the initial baud rate of the serial
channel is automatically set to 9600 bps.
automatic baud rate setting in the 1st byte. If automatic baud rate setting fails,
the boot program stops operation.
information of the boot program in ASCII code. The PC should check that the
correct version of the boot program is used.
should check that the frequency of the resonator is measured correctly.
frequency
Table 3.4.8 Baud Rate Modification Command
Table 3.4.10 Version Management Information
(MHz)
Table 3.4.11 data of measuring frequency
FRM1
C0H
9600
28H
Table 3.4.9 Operation Command
92CF26A-52
6.000
09H
19200
18H
46H, 52H, 4DH, 31H
8.000
User program start
0AH
ASCII Code
Operation
38400
07H
9.000
08H
10.000
57600
0BH
06H
115200
TMP92CF26A
03H
2007-11-21

Related parts for TMP92CF26AXBG