Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
d) Notes on Intel Hex format (binary)
1.
3.
4.
6.
2.
5.
Example: How to convert an Intel Hex file into binary format
Once the PC program has finished sending the checksum of an end record, it
must wait for 2 bytes of data (upper and lower bytes of SUM) before sending
any other data. This is because after receiving the checksum of an end record,
the boot program calculates SUM and returns the result to the PC in 2 bytes.
area.
Addresses 3000H to 21FFFH are allocated as the user program download
After receiving the checksum of a record, the boot program waits for the start
mark (3AH for “:”) of the next record. If data other than 3AH is received
between records, it is ignored.
Writing to areas other than internal RAM may cause incorrect operation. To
transfer a record, set the paragraph address to 0000H.
Since the address pointer is initially set to 00H, the record type to be
transferred first does not have to be an address record.
A user program in Intel Hex format (ASCII codes) must be converted into
binary data in advance, as explained in the example below.
Intel Hex format
Data record
End record
ASCII Code
The following shows how an Intel Hex format file is displayed on a text editor.
However, the actual data consists of ASCII codes, as shown below.
Thus, the ASCII codes must be converted into binary data based on the conversion rules
shown in the table below.
30 to 39
41 or 61
42 or 62
43 or 63
44 or 64
45 or 65
46 or 66
0D0A
3A
: 103000000607F100030000F201030000B1F16010B7
: 00000001FF
3A3130333030303030303630374631303030333030303046323031303330303030
423146313630313042370D0A3A303030303030303146460D0A
92CF26A-55
: (Start mark)
3A 10 3000 00 0607F100030000F201030000B1F16010 B7
3A 00 0000 01 FF
: (Start mark)
3A (Only 3A remains the same.)
Record length
Record length
Address
Address
Binary Data
Delete
0 to 9
Record type
Record type
C
D
A
B
E
F
Data
Data
TMP92CF26A
2007-11-21
Checksum