HD64F2638F20J Renesas Electronics America, HD64F2638F20J Datasheet - Page 116

IC H8S MCU FLASH 256K 128-QFP

HD64F2638F20J

Manufacturer Part Number
HD64F2638F20J
Description
IC H8S MCU FLASH 256K 128-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2638F20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
Motor Control PWM, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2638F20J
Manufacturer:
PENESAS
Quantity:
252
H8S/2639, H8S/2638, H8S/2636,
H8S/2630, H8S/2635 Group
Section 2 CPU
(2) Reset Exception Handling
After the RES pin has gone low and the reset state has been entered, when RES goes high again,
reset exception handling starts. The CPU enters the reset state when the RES is low. When reset
exception handling starts the CPU fetches a start address (vector) from the exception vector table
and starts program execution from that address. All interrupts, including NMI, are disabled during
reset exception handling and after it ends.
(3) Traces
Traces are enabled only in interrupt control mode 2. Trace mode is entered when the T bit of EXR
is set to 1. When trace mode is established, trace exception handling starts at the end of each
instruction.
At the end of a trace exception-handling sequence, the T bit of EXR is cleared to 0 and trace mode
is cleared. Interrupt masks are not affected.
The T bit saved on the stack retains its value of 1, and when the RTE instruction is executed to
return from the trace exception-handling routine, trace mode is entered again. Trace exception-
handling is not executed at the end of the RTE instruction.
Trace mode is not entered in interrupt control mode 0, regardless of the state of the T bit.
(4) Interrupt Exception Handling and Trap Instruction Exception Handling
When interrupt or trap-instruction exception handling begins, the CPU references the stack pointer
(ER7) and pushes the program counter and other control registers onto the stack. Next, the CPU
alters the settings of the interrupt mask bits in the control registers. Then the CPU fetches a start
address (vector) from the exception vector table and program execution starts from that start
address.
Figure 2-16 shows the stack after exception handling ends.
Page 66 of 1458
REJ09B0103-0800 Rev. 8.00
May 28, 2010

Related parts for HD64F2638F20J